To the Editor:

In a recent publication in BLOOD, Chalmers et al1presented data on cytokine production of lymphocytes at the single-cell level using three-color flow cytometry. A total of 6 blood samples have been investigated. Their main finding was the lower production of interleukin-2 (IL-2), IL-4, interferon-γ (IFN-γ), and tumor necrosis factor-α (TNF-α) by cord blood lymphocytes compared with peripheral blood lymphocytes derived from adults. The investigators concluded that the reduced incidence of graft-versus-host disease in cord blood transplantation may be due to this altered cytokine profile. Performing as well the intracytoplasmic detection of cytokines by flow cytometry on 20 cord blood and 34 adult blood specimens, our results confirm a diminished ability of cord blood lymphocytes to produce IL-2 and IFN-γ (Table 1). However, we found a strikingly lower relative amount of IFN-γ–positive cells (4%v ∼25%1) and a clearly decreased IL-2 expression per cell, suggesting a more pronounced defective cellular immune response in neonates.

Table 1.

Reduced Capacity of Neonatal T Lymphocytes to Produce IL-2 and IFN-γ

Cord Blood (n = 20) Adult Blood (n = 34)P Value*
IL-2 producing cells (%)  17 (13-26) 34 (28-37)  <.0001  
IL-2 expression per cell (MFI) 8 (7-9)  14 (12-15)  <.0001  
IFN-γ producing cells (%)  4 (3-5)  18 (14-20)  <.0001  
IFN-γ expression per cell (MFI)  3.5 (3-4)  12 (10-15) <.0001 
Cord Blood (n = 20) Adult Blood (n = 34)P Value*
IL-2 producing cells (%)  17 (13-26) 34 (28-37)  <.0001  
IL-2 expression per cell (MFI) 8 (7-9)  14 (12-15)  <.0001  
IFN-γ producing cells (%)  4 (3-5)  18 (14-20)  <.0001  
IFN-γ expression per cell (MFI)  3.5 (3-4)  12 (10-15) <.0001 

Values are expressed as the median of cytokine producing cells (%) and the cytokine expression per cell (mean fluorescence intensity [MFI]), with the interquartile range in parentheses. After stimulation with phorbol myristate acetate and ionomycin, the production of IL-2 and IFN-γ is significantly lower in cord blood than in adult blood lymphocytes analyzed at the single-cell level by flow cytometry.

*

Statistical differences comparing the two groups were tested by the nonparametric Mann-Whitney U test.

These discrepancies can be explained by different technical methods. Chalmers et al1 used isotype-specific antimouse antibodies to discriminate specific versus nonspecific staining. Although these antibodies are essential in the detection of irrelevant specificity of surface molecule staining, they are inadequate negative controls for intracellular staining, because they do not cover the enhancement of unspecific binding during fixation.2 We compared isotype-specific antimouse antibodies to an excess of unlabeled anticytokine antibodies as negative controls (provided by PharMingen, San Diego, CA) in 12 cord blood and 23 adult blood samples. We found that positively and negatively stained cells cannot be exactly differentiated by the use of isotype-specific antimouse antibodies. Because of a high false-positive rate, ranging between 5% and 34% (data not shown), the number of specifically stained cells may be overestimated. We therefore emphasize that only the use of adequate negative controls such as unlabeled anticytokine antibodies enables a meaningful interpretation of data obtained by flow cytometric detection of intracytoplasmic cytokines. The technique of cell separation performing density gradient centrifugation (Ficoll-Hypaque) used in the study of Chalmers et al1 also requires further comment. Although these preparations provide useful information about individual cell types, functional responses of purified cell preparations may not represent physiological reactions occuring in vivo. De Groote et al3 clearly demonstrated that density gradient centrifugation may affect cell activation status, resulting in considerably altered cytokine production compared with whole blood culture technique. Whole blood containing physiological levels of regulatory cytokines may therefore more closely approximate circulating cells in vivo and better reflect disease state alterations. To avoid artificial modifying effects on cell function, we preferred the whole blood assay4 before flow cytometric analysis of intracytoplasmic cytokines.

Additionally, we would like to comment on the decreased production of TNF-α by cord blood lymphocytes.1 This observation could be misinterpreted as a diminished capacity of neonates to produce inflammatory cytokines. However, it should be kept in mind that monocytes are a major cellular source for this cytokine. Andersson et al5 had already shown that cord blood monocytes were able to produce TNF-α at the single-cell level. Moreover, we found an increased amount of IL-6–positive monocytes in cord blood versus adult blood (Table 2). Because IL-6 represents a further step in the lipopolysaccharide-induced cytokine cascade after TNF-α secretion, these results support a well-developed inflammatory reaction in neonates.

Table 2.

Increased Production of IL-6 in Neonatal Monocytes Compared With Adult Monocytes

Cord Blood (n = 20) Adult Blood (n = 30)P Value*
IL-6 producing cells (%)  63 (57-66) 50 (42-60)  <.001   
IL-6 expression per cell (MFI) 14 (13-16)  9 (8-10)  <.0001 
Cord Blood (n = 20) Adult Blood (n = 30)P Value*
IL-6 producing cells (%)  63 (57-66) 50 (42-60)  <.001   
IL-6 expression per cell (MFI) 14 (13-16)  9 (8-10)  <.0001 

Values are expressed as the median of cytokine producing cells (%) and the cytokine expression per cell (mean fluorescence intensity [MFI]), with the interquartile range in parentheses. After stimulation with lipopolysaccharide, the production of IL-6 is significantly higher in cord blood than in adult blood monocytes analyzed at the single-cell level by flow cytometry.

*

Statistical differences comparing the two groups were tested by the nonparametric Mann-Whitney U test.

In summary, our results based on a larger series show an even more decreased cellular immune response in neonates, characterized by a profoundly reduced production of IL-2 and IFN-γ. However, the ability of neonatal monocytes to produce TNF-α5 and IL-6 (Table2) suggests that an impaired inflammatory response is not responsible for the reduced incidence of graft-versus-host disease in cord blood transplantation. To clarify these and other questions in neonatal immunology, the method presented here has the potential to become the standard assay for examining cytokine production at the single-cell level. Adequate negative controls and the whole blood culture technique instead of cell separation should be preferred to prevent misinterpretation of data.

Supported in part by Lübeck-Hilfe für krebskranke Kinder, e.V.

1
Chalmers
 
IMH
Janossy
 
G
Contreras
 
M
Navarrete
 
C
Intracellular cytokine profile of cord and adult blood lymphocytes.
Blood
92
1998
11
2
Prussin
 
C
Metcalfe
 
DD
Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies.
J Immunol Methods
188
1995
117
3
De Groote
 
D
Zangerle
 
PF
Gevaert
 
Y
Fassotte
 
MF
Beguin
 
Y
Noizat-Pirenne
 
F
Pirenne
 
J
Gathy
 
R
Lopez
 
M
Dehart
 
I
Igot
 
D
Baudrihaye
 
M
Delacroix
 
D
Franchimont
 
P
Direct stimulation of cytokines (IL-1β, TNF-α, IL-6, IL-2, IFN-γ, and GM-CSF) in whole blood. I. Comparison with isolated PBMC stimulation.
Cytokine
4
1992
239
4
Sewell
 
WAC
North
 
ME
Webster
 
ADB
Farrant
 
J
Determination of intracellular cytokines by flow-cytometry following whole-blood culture.
J Immunol Methods
209
1997
67
5
Andersson
 
U
Andersson
 
J
Lindfors
 
A
Heusser
 
C
Möller
 
G
Restricted cytokine production by cord blood mononuclear cells
Neonatal Haematology and Immunology.
Bracci
 
R
Xanthou
 
M
1991
141
Elsevier
Amsterdam, The Netherlands
Sign in via your Institution