Pulmonary embolism (PE) is a common, potentially life-threatening yet treatable condition. Prompt diagnosis and expeditious therapeutic intervention is of paramount importance for optimal patient management. Our objective was to systematically review the accuracy of D-dimer assay, compression ultrasonography (CUS), computed tomography pulmonary angiography (CTPA), and ventilation-perfusion (V/Q) scanning for the diagnosis of suspected first and recurrent PE. We searched Cochrane Central, MEDLINE, and EMBASE for eligible studies, reference lists of relevant reviews, registered trials, and relevant conference proceedings. 2 investigators screened and abstracted data. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework. We pooled estimates of sensitivity and specificity. The review included 61 studies. The pooled estimates for D-dimer sensitivity and specificity were 0.97 (95% confidence interval [CI], 0.96-0.98) and 0.41 (95% CI, 0.36-0.46) respectively, whereas CTPA sensitivity and specificity were 0.94 (95% CI, 0.89-0.97) and 0.98 (95% CI, 0.97-0.99), respectively, and CUS sensitivity and specificity were 0.49 (95% CI, 0.31-0.66) and 0.96 (95% CI, 0.95-0.98), respectively. Three variations of pooled estimates for sensitivity and specificity of V/Q scan were carried out, based on interpretation of test results. D-dimer had the highest sensitivity when compared with imaging. CTPA and V/Q scans (high probability scan as a positive and low/non-diagnostic/normal scan as negative) both had the highest specificity. This systematic review was registered on PROSPERO as CRD42018084669.

Pulmonary embolism (PE) is a common, potentially life-threatening yet treatable condition.1-7  The annual incidence of PE is 60 to 70 cases per 100 000. In the United States and Europe, PE accounts for 100 000 and 300 000 annual deaths, respectively.8-10  Consequently, prompt diagnosis and expeditious therapeutic intervention is of paramount importance for optimal patient management.11 

Excluding PE is also of paramount importance because of the bleeding risks of anticoagulation and costs associated with treatment and monitoring. Various strategies are currently used to evaluate patients with suspected PE. Commonly used tests include D-dimer assays, compression ultrasonography (CUS), computed tomography pulmonary angiography (CTPA), and ventilation-perfusion (V/Q) scanning. The tests each have benefits and limitations. Imaging tests for PE such as CTPA and V/Q lung scanning are expensive, time-consuming, and are associated with radiation exposure. In addition, the contrast used in CTPA can cause nephrotoxicity and allergic-like reactions. Therefore, to exclude PE efficiently, patients undergo initial tests that are cost-effective with low risk; tests such as CTPA and V/Q are reserved for patients in whom PE was not initially excluded.12 

The aim of this systematic review is to determine the accuracy of commonly available diagnostic tests for PE, which can be used to inform a combined strategy for diagnosis. Pooled estimates of sensitivity and specificity obtained in this systematic review were used to model different diagnostic strategies for patients with suspected PE. The results of modeling were used to inform evidence-based recommendations on diagnostic strategies for deep vein thrombosis (DVT) in the American Society of Hematology clinical practice guidelines for diagnosis of venous thromboembolism.13 

Search strategy and data sources

We searched MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials from inception until May 2019. We also manually searched the reference lists of relevant articles and existing reviews. Studies published in any language were included in this review. We limited the search to studies reporting data for accuracy of diagnostic tests. The complete search strategy is available in supplemental Material 1. The prespecified protocol for this review is registered on PROSPERO (registration number CRD42018084669). This review is reported in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses for diagnostic test accuracy guidelines.13 

Study selection

Studies.

Studies reporting data on diagnostic test accuracy (randomized control trials, cohort studies, cross-sectional studies) for PE were eligible for inclusion in this systematic review.

Participants.

Adult patients ≥18 years of age, presenting to inpatient or outpatient settings with suspected first or recurrent episode of PE were eligible for inclusion

Index tests for diagnosis.

Studies assessing test accuracy of V/Q scan, multidetector CTPA, CUS, and D-dimer assays at standard cutoffs (Vidas ELISA Assay at 500 ng/mL, STA Liatest D-Di Assay at 500 ng/mL, Tina-quant D-dimer Assay at 500 ng/mL, Innovance D-dimer at 500 ng/mL, and HemoSIL D-dimer Assay at 230 ng/mL) to diagnose a first or recurrent episode of symptomatic PE.

Reference standards.

Angiography, positive lower extremity ultrasound for DVT in the setting of suspicion for PE, and/or clinical follow-up were eligible as a reference standard for V/Q scan or CTPA. V/Q scan, CTPA, compression ultrasound for DVT in the setting of suspicion for PE, and/or clinical follow-up were considered appropriate reference standards for D-dimer assays. If a reference diagnostic test was not conducted, clinical follow-up for symptoms alone was sufficient as a reference standard.

Exclusion criteria.

Exclusion criteria was determined by unanimous guideline panel consensus. We excluded studies that did not provide sufficient data to determine test accuracy (sensitivity and specificity) and abstracts published before 2014 because the complete studies were likely published in peer-reviewed journals. Studies with sample size <100 patients were excluded to increase feasibility. A sensitivity analysis was performed and indicated that this would not affect the pooled test accuracy estimates. The quality of small test accuracy studies informing a clinical practice guideline was a concern; therefore, these studies were excluded.

Patients that were asymptomatic and pregnant were excluded. Studies reporting on both adult and pediatric patients were eligible for inclusion but were excluded when >80% of the study sample was younger than 18 years of age or if the mean age was younger than 25 years. When possible, we extracted data separately for adult patients from these studies.

Studies that used unsuitable reference standards were excluded (V/Q single-photon emission CT, transthoracic ultrasound, single-detector CT, impedance plethysmography, and D-dimer). D-dimer studies were excluded if they used assays that are no longer in use and/or are not highly sensitive (MDA, Asserachrom, Dimertest I, Enzygnost, Fibrinostika FbDP, Acculot, Wellcotest, Minutex), if they used a nonquantitative assay (SimpliRed), or if they considered a positive threshold other than the defined clinical cutoffs.

We excluded studies evaluating V/Q test accuracy that were published before the year 2000 unless it included a screening process with chest radiograph or other testing before V/Q testing. Finally, we excluded studies that did not provide a breakdown of the V/Q scan interpretation (normal, low/intermediate, and high probability).

Screening and data extraction

Independent reviewers conducted title and abstract screening and full-text review in duplicate to identify eligible studies. Data extraction was also conducted independently and in duplicate and verified by a third author (R.M.). Disagreements were resolved by discussion to reach consensus, in consultation with 2 expert clinician scientists (R.M. and W.L.). Data extracted included general study characteristics (authors, publication year, country, study design), diagnostic index test and reference standard, prevalence of PE, and parameters to determine test accuracy (ie, sensitivity and specificity of the index test).

Risk of bias and certainty of evidence

We conducted the risk of bias assessment for diagnostic test accuracy studies using the Quality Assessment of Diagnostic Accuracy Studies-2 revised tool.14 

The Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework was used to assess overall certainty by evaluating the evidence for each outcome on the following domains: risk of bias, imprecision, inconsistency, indirectness, and publication bias.15,16 

Data synthesis

The accuracy estimates from individual studies were combined quantitatively (pooled) for each test using OpenMetaAnalyst (http://www.cebm.brown.edu/openmeta/). We conducted a bivariate analysis for pooling sensitivity and specificity for each of the test comparisons to account for variation within and between studies. Forest plots were created for each comparison. The Breslow-Day test was used to measure the percentage of total variation across studies because of heterogeneity; however, the results did not influence our judgment of the pooled estimates because the literature has discouraged its use for test accuracy.17  To better illustrate the impact of the sensitivity and specificity, absolute differences in effects were calculated for each comparison as true positives, true negatives, false positives, and false negatives.

Diagnostic strategies for PE are based on assessment of the pretest probability (PTP) for individual patients, which provides an estimate of the expected prevalence of PE at a population level. Prevalence estimates for PE were obtained from a meta-analysis of 29 studies of 31 215 patients in which the 3-level Wells score was evaluated in 14 studies.18  The pooled prevalence of PE in these studies was 5.7% in the low PTP, 23.2% in the intermediate PTP, and 49.3% in the high PTP category. We used similar disease prevalence estimates to determine the absolute differences in effects among patients with clinical suspicion of PE: 5% corresponding approximately to low PTP, 20% for intermediate PTP, and 50% and 75% for high PTP. The review also discusses recurrent PE for which the prevalence was modeled at 30% and 40%. We calculated the absolute differences in effects for each comparison as true positives, true negatives, false positives, and false negatives. Here, we present the results for the low PTP population; results for intermediate and high PTP groups are reported in supplemental Material 2.

Description of studies

Among the 15 453 nonduplicate records identified from the initial electronic database search and from other sources, 355 articles in full text were retrieved after title and abstract screening. An updated search of the electronic database was performed with 1391 nonduplicate records identified. Of these, 21 articles in full text were retrieved after title and abstract screening. After exclusion of articles, a total of 61 studies were included for data abstraction. A list of excluded studies is provided in supplemental Material 3. Reasons for exclusion at full-text review or data abstraction stages were ineligible study design (n = 67), study population (n = 45), diagnostic test (n = 46), full text not available (n = 19), or unacceptable reference standards and/or studies did not provide enough information to determine sensitivity and specificity (n = 139). Figure 1 shows the study flow diagram for included studies.

Figure 1.

Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagram for study selection.

Figure 1.

Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagram for study selection.

Close modal

First-episode PE studies reported the test accuracy of the following index tests in comparison with a reference standard: 34 studies on D-dimer,19-52  1 study on age-adjusted D-dimer,43  16 studies on CTPA,26,28,35,38,42,43,53-62  7 studies on compression ultrasound,42,63-68  and 13 studies V/Q scan.26,53,57,67-76  Recurrent PE studies reported test accuracy from 3 studies.77-79 Table 1 summarizes general characteristics of included studies, as well the index and reference standards. The majority of included studies were judged to be low risk of bias for patient selection, index test, and reference standard interpretation. Although there was unclear reporting regarding flow and timing in some studies, the certainty of evidence was generally not downgraded for risk of bias. The complete risk of bias assessment for individual studies is included in supplemental Material 4.

Table 1.

Summary of included studies for the diagnosis of suspected pulmonary embolism

Study author, year (reference)PopulationClinical settingIndex testReference standard
1. Abcarian et al, 2004 (19Patients with suspected PE Inpatient and outpatient D-dimer Pulmonary CT angiography 
2. Anderson et al, 2007 (53Patients with suspected PE Inpatient and outpatient Pulmonary CT angiography V/Q scan 
3. Bajc et al, 2002 (54Patients with suspected PE Inpatient and outpatient V/Q scan and helical computed tomography (CT) V/Q scan and helical CT 
4. Blachere et al, 2000 (69Patients with suspected PE Inpatient Helical CT angiography, V/Q scan Doppler sonography of the veins of the legs 
Pulmonary angiography 
5. Bounameaux et al, 1991 (70Patients with suspected PE Inpatient and outpatient V/Q scan CTPA 
6. Bosson et al, 2005 (20Patients with suspected PE Inpatient and outpatient D-dimer Doppler sonography of the veins of the legs 
V/Q scan 
HCT 
Pulmonary angiography 
7. Crane et al, 2018 (49Patients with suspected PE Emergency department D-dimer CTPA 
V/Q scan 
CUS 
8. de Monyé et al, 2002 (22Patients with suspected PE Inpatient and outpatient D-dimer CTPA 
V/Q scan 
CUS 
9. den Exter et al, 2013 (23Patients with suspected PE Inpatient and outpatient D-dimer CTPA 
10. Di Nisio et al, 2005 (24Cancer patients with suspected PE Inpatient and outpatient D-dimer Normal spiral CT scan and normal ultrasonography, or spiral CT or pulmonary angiography V/Q scan 
11. Dunn et al, 2002 (25Patients with suspected PE Outpatient D-dimer V/Q scan, chest CT, or pulmonary angiography 
12. Elias et al, 2004 (26Patients with suspected PE Inpatients and outpatients Lower limb venous ultrasound V/Q scan 
D-dimer 
CT scan 
13. Emet et al, 2007 (27Patient with prediagnosed PE Outpatient CT pulmonary angiogram V/Q scan 
D-dimer 
14. Eng et al, 2009 (28Patients with suspected PE Inpatient D-dimer CTPA 
15. Freitas et al, 1995 (71Patients with suspected PE Unclear V/Q scan Pulmonary angiography 
16. Friera-Reyes et al, 2005 (29Patients with suspected PE Outpatient D-dimer Chest radiograph, perfusion scintigraphy, venous ultrasound of lower limbs, spiral CT, and pulmonary arteriography 
17. Froehling et al, 2007 (30Patients with suspected PE Inpatients and outpatients D-dimer CT angiography 
18. Garcia Bolado et al, 2003 (63Patients with suspected PE Emergency department CUS CTPA 
19. Ghanima et al, 2006 (31Patients with suspected PE Outpatients D-dimer Multislice CT 
20. Goekoop et al, 2007 (32Patients with suspected PE Outpatients D-dimer CT scan 
VQ scan 
21. Guilabert et al, 2007 (67Patients with suspected PE Inpatient Multislice CT VQ scan 
Doppler US 
22. Hantous-Zannad et al, 2010 (55Patients with suspected PE Inpatient CTPA Unclear 
23. Jiménez et al, 2006 (56Patients with suspected PE Unclear CT angiogram VQ scan 
Doppler US 
24. Kabrhel, 2008 (51Patients with suspected PE Emergency department D-dimer CT angiogram 
VQ scan 
Doppler US of leg veins 
25. Kim et al, 1999 (64Patients with suspected PE Inpatient and outpatient Spiral CT scan V/Q scan 
Doppler US of leg veins 
Pulmonary angiography 
26. Le Gal et al, 2006 (77Patient with clinically suspected recurrent acute PE Outpatient Doppler ultrasound of lower limbs Multislice CT 
27. Leclercq et al, 2003 (33Patients with suspected PE Inpatient and outpatient D-dimer VQ Scan Doppler Ultrasonography and pulmonary angiography 
28. Mac Gillavry et al, 2000 (65Patients with suspected PE Inpatient and outpatient Doppler ultrasonography Perfusion lung scintigraph 
Pulmonary angiography 
29. Macdonald et al, 2005 (57Patients with suspected PE Unclear VQ scan CT pulmonary angiography 
30. Megyeri et al, 2014 (59Patients with suspected PE Unclear CT pulmonary angiography VQ scan 
Doppler ultrasonography 
31. Miron et al, 1999 (72Patients with suspected PE Inpatients D-dimer V/Q scan 
Doppler ultrasonography 
Pulmonary angiography 
32. de Moerloose et al, 1996 (21Patients with suspected PE Outpatient D-dimer V/Q scan 
Doppler ultrasonography 
Pulmonary angiography 
33. Moores et al, 2016 (58Patients with suspected PE Outpatient CTPA V/Q scan 
Venous ultrasonograph 
Pulmonary angiograph 
34. Mos et al, 2014 (78Patient with clinically suspected recurrent acute PE Inpatient D-dimer CTPA 
35. Nijkeuter et al, 2007 (79Patients with clinical suspicion of recurrent PE Inpatient and outpatient D-dimer CTPA 
36. Oger et al, 1998 (34Patients with suspected PE Outpatient D-dimer V/Q scan 
Venous ultrasonograph 
Pulmonary angiography 
37. Pacouret et al, 2002 (35Patients with suspected PE Outpatient D-dimer Helicoidal thoracic scanner 
Venous Doppler of the lower limbs 
Pulmonary scintigraphy 
38. Palud et al, 2004 (36Patients with suspected PE Unclear D-dimer CTPA 
Pulmonary angiogram 
Doppler US 
39. Parent et al, 2007 (37Patients with suspected PE Inpatient and outpatient D-dimer CTPA 
Doppler US 
Pulmonary angiogram 
V/Q lung scan 
40. Pérez de Llano et al, 2006 (60Patients with suspected PE Outpatient Helical CT Venous ultrasonography 
41. Pernod et al, 2017 (50Patients with suspected PE Outpatient D-dimer CTPA 
V/Q scan 
Pulmonary arteriography 
42. Perrier et al, 1996 (68Patients with suspected PE Outpatient V/Q scan, D-dimer and Doppler ultrasonography Pulmonary angiography 
43. Perrier et al, 1999 (39Patients with suspected PE Outpatient D-dimer, lower-limb venous compression ultrasonography, and V/Q scan Phlebography and pulmonary angiography 
44. Perrier et al, 2004 (40Patients with suspected PE Outpatient D-dimer, lower limb venous ultrasonography, and helical CT Pulmonary angiography 
45. Perrier et al, 2005 (38Patients with suspected PE Outpatient D-dimer measurement and multidetector-row CT Lower-limb ultrasonography 
46. Quinn et al, 1999 (41Patients with suspected PE Unclear D-dimer Pulmonary angiography 
47. Righini et al, 2008 (42Patients with suspected PE Outpatient D-dimer Venous ultrasonography 
48. Righini et al, 2014 (43Patients with suspected PE Outpatient D-dimer V/Q scan, CTPA, angiography 
49. Sijens et al, 2000 (44Patients with suspected PE Inpatient D-dimer Pulmonary angiography 
50. Söderberg et al, 2009 (45Patients with suspected PE Outpatient D-dimer CTPA, angiography 
51. Spies et al, 1986 (73Patients with suspected PE Unclear V/Q scan Pulmonary angiography 
52. Stein et al, 2006 (61Patients with suspected PE Inpatient and outpatient Multidetector CTPA V/Q scan, ultrasonography, pulmonary digital-subtraction angiography 
53. Subramaniam et al, 2007 (62Patients with suspected PE Unclear CTPA Unclear 
54. Szturmowicz et al, 2015 (46Patients with suspected PE Unclear D-dimer CTPA 
55. Toulon et al, 2004 (47Patients with suspected PE Outpatient D-dimer V/Q scan, spiral CT, pulmonary digital-subtraction angiography. 
56. Turan et al, 2017 (52Patients with suspected PE Outpatient CTPA D-dimer 
57. Turkstra et al, 1997 (66Patients with suspected PE Inpatient and outpatient Compression ultrasonography V/Q scan and angiography 
58. van Rossum et al, 1996 (75Patients with suspected PE Unclear Spiral volumetric computed tomographic V/Q scan, ultrasonography of the legs 
59. van Rossum et al, 1998 (74Patients with suspected PE Mostly outpatient Helical CT V/Q scan 
60. Verschuren et al, 2003 (48Patients with suspected PE Emergency department D-dimer CTPA 
V/Q scan 
CUS 
Pulmonary arteriography 
61. Wells et al, 2000 (76Patients with suspected PE Unclear D-dimer V/Q scan, compression ultrasonography 
Study author, year (reference)PopulationClinical settingIndex testReference standard
1. Abcarian et al, 2004 (19Patients with suspected PE Inpatient and outpatient D-dimer Pulmonary CT angiography 
2. Anderson et al, 2007 (53Patients with suspected PE Inpatient and outpatient Pulmonary CT angiography V/Q scan 
3. Bajc et al, 2002 (54Patients with suspected PE Inpatient and outpatient V/Q scan and helical computed tomography (CT) V/Q scan and helical CT 
4. Blachere et al, 2000 (69Patients with suspected PE Inpatient Helical CT angiography, V/Q scan Doppler sonography of the veins of the legs 
Pulmonary angiography 
5. Bounameaux et al, 1991 (70Patients with suspected PE Inpatient and outpatient V/Q scan CTPA 
6. Bosson et al, 2005 (20Patients with suspected PE Inpatient and outpatient D-dimer Doppler sonography of the veins of the legs 
V/Q scan 
HCT 
Pulmonary angiography 
7. Crane et al, 2018 (49Patients with suspected PE Emergency department D-dimer CTPA 
V/Q scan 
CUS 
8. de Monyé et al, 2002 (22Patients with suspected PE Inpatient and outpatient D-dimer CTPA 
V/Q scan 
CUS 
9. den Exter et al, 2013 (23Patients with suspected PE Inpatient and outpatient D-dimer CTPA 
10. Di Nisio et al, 2005 (24Cancer patients with suspected PE Inpatient and outpatient D-dimer Normal spiral CT scan and normal ultrasonography, or spiral CT or pulmonary angiography V/Q scan 
11. Dunn et al, 2002 (25Patients with suspected PE Outpatient D-dimer V/Q scan, chest CT, or pulmonary angiography 
12. Elias et al, 2004 (26Patients with suspected PE Inpatients and outpatients Lower limb venous ultrasound V/Q scan 
D-dimer 
CT scan 
13. Emet et al, 2007 (27Patient with prediagnosed PE Outpatient CT pulmonary angiogram V/Q scan 
D-dimer 
14. Eng et al, 2009 (28Patients with suspected PE Inpatient D-dimer CTPA 
15. Freitas et al, 1995 (71Patients with suspected PE Unclear V/Q scan Pulmonary angiography 
16. Friera-Reyes et al, 2005 (29Patients with suspected PE Outpatient D-dimer Chest radiograph, perfusion scintigraphy, venous ultrasound of lower limbs, spiral CT, and pulmonary arteriography 
17. Froehling et al, 2007 (30Patients with suspected PE Inpatients and outpatients D-dimer CT angiography 
18. Garcia Bolado et al, 2003 (63Patients with suspected PE Emergency department CUS CTPA 
19. Ghanima et al, 2006 (31Patients with suspected PE Outpatients D-dimer Multislice CT 
20. Goekoop et al, 2007 (32Patients with suspected PE Outpatients D-dimer CT scan 
VQ scan 
21. Guilabert et al, 2007 (67Patients with suspected PE Inpatient Multislice CT VQ scan 
Doppler US 
22. Hantous-Zannad et al, 2010 (55Patients with suspected PE Inpatient CTPA Unclear 
23. Jiménez et al, 2006 (56Patients with suspected PE Unclear CT angiogram VQ scan 
Doppler US 
24. Kabrhel, 2008 (51Patients with suspected PE Emergency department D-dimer CT angiogram 
VQ scan 
Doppler US of leg veins 
25. Kim et al, 1999 (64Patients with suspected PE Inpatient and outpatient Spiral CT scan V/Q scan 
Doppler US of leg veins 
Pulmonary angiography 
26. Le Gal et al, 2006 (77Patient with clinically suspected recurrent acute PE Outpatient Doppler ultrasound of lower limbs Multislice CT 
27. Leclercq et al, 2003 (33Patients with suspected PE Inpatient and outpatient D-dimer VQ Scan Doppler Ultrasonography and pulmonary angiography 
28. Mac Gillavry et al, 2000 (65Patients with suspected PE Inpatient and outpatient Doppler ultrasonography Perfusion lung scintigraph 
Pulmonary angiography 
29. Macdonald et al, 2005 (57Patients with suspected PE Unclear VQ scan CT pulmonary angiography 
30. Megyeri et al, 2014 (59Patients with suspected PE Unclear CT pulmonary angiography VQ scan 
Doppler ultrasonography 
31. Miron et al, 1999 (72Patients with suspected PE Inpatients D-dimer V/Q scan 
Doppler ultrasonography 
Pulmonary angiography 
32. de Moerloose et al, 1996 (21Patients with suspected PE Outpatient D-dimer V/Q scan 
Doppler ultrasonography 
Pulmonary angiography 
33. Moores et al, 2016 (58Patients with suspected PE Outpatient CTPA V/Q scan 
Venous ultrasonograph 
Pulmonary angiograph 
34. Mos et al, 2014 (78Patient with clinically suspected recurrent acute PE Inpatient D-dimer CTPA 
35. Nijkeuter et al, 2007 (79Patients with clinical suspicion of recurrent PE Inpatient and outpatient D-dimer CTPA 
36. Oger et al, 1998 (34Patients with suspected PE Outpatient D-dimer V/Q scan 
Venous ultrasonograph 
Pulmonary angiography 
37. Pacouret et al, 2002 (35Patients with suspected PE Outpatient D-dimer Helicoidal thoracic scanner 
Venous Doppler of the lower limbs 
Pulmonary scintigraphy 
38. Palud et al, 2004 (36Patients with suspected PE Unclear D-dimer CTPA 
Pulmonary angiogram 
Doppler US 
39. Parent et al, 2007 (37Patients with suspected PE Inpatient and outpatient D-dimer CTPA 
Doppler US 
Pulmonary angiogram 
V/Q lung scan 
40. Pérez de Llano et al, 2006 (60Patients with suspected PE Outpatient Helical CT Venous ultrasonography 
41. Pernod et al, 2017 (50Patients with suspected PE Outpatient D-dimer CTPA 
V/Q scan 
Pulmonary arteriography 
42. Perrier et al, 1996 (68Patients with suspected PE Outpatient V/Q scan, D-dimer and Doppler ultrasonography Pulmonary angiography 
43. Perrier et al, 1999 (39Patients with suspected PE Outpatient D-dimer, lower-limb venous compression ultrasonography, and V/Q scan Phlebography and pulmonary angiography 
44. Perrier et al, 2004 (40Patients with suspected PE Outpatient D-dimer, lower limb venous ultrasonography, and helical CT Pulmonary angiography 
45. Perrier et al, 2005 (38Patients with suspected PE Outpatient D-dimer measurement and multidetector-row CT Lower-limb ultrasonography 
46. Quinn et al, 1999 (41Patients with suspected PE Unclear D-dimer Pulmonary angiography 
47. Righini et al, 2008 (42Patients with suspected PE Outpatient D-dimer Venous ultrasonography 
48. Righini et al, 2014 (43Patients with suspected PE Outpatient D-dimer V/Q scan, CTPA, angiography 
49. Sijens et al, 2000 (44Patients with suspected PE Inpatient D-dimer Pulmonary angiography 
50. Söderberg et al, 2009 (45Patients with suspected PE Outpatient D-dimer CTPA, angiography 
51. Spies et al, 1986 (73Patients with suspected PE Unclear V/Q scan Pulmonary angiography 
52. Stein et al, 2006 (61Patients with suspected PE Inpatient and outpatient Multidetector CTPA V/Q scan, ultrasonography, pulmonary digital-subtraction angiography 
53. Subramaniam et al, 2007 (62Patients with suspected PE Unclear CTPA Unclear 
54. Szturmowicz et al, 2015 (46Patients with suspected PE Unclear D-dimer CTPA 
55. Toulon et al, 2004 (47Patients with suspected PE Outpatient D-dimer V/Q scan, spiral CT, pulmonary digital-subtraction angiography. 
56. Turan et al, 2017 (52Patients with suspected PE Outpatient CTPA D-dimer 
57. Turkstra et al, 1997 (66Patients with suspected PE Inpatient and outpatient Compression ultrasonography V/Q scan and angiography 
58. van Rossum et al, 1996 (75Patients with suspected PE Unclear Spiral volumetric computed tomographic V/Q scan, ultrasonography of the legs 
59. van Rossum et al, 1998 (74Patients with suspected PE Mostly outpatient Helical CT V/Q scan 
60. Verschuren et al, 2003 (48Patients with suspected PE Emergency department D-dimer CTPA 
V/Q scan 
CUS 
Pulmonary arteriography 
61. Wells et al, 2000 (76Patients with suspected PE Unclear D-dimer V/Q scan, compression ultrasonography 

D-dimer

Test accuracy data for D-dimer were pooled from 34 studies, with a total of 22 849 participants.19-52  The Vidas D-dimer assay had a sensitivity of 0.97 (95% confidence interval [CI], 0.95-0.99) and a specificity of 0.41 (95% CI, 0.36-0.46), Tina-quant D-dimer had a sensitivity of 0.92 (95% CI, 0.83-0.96) and a specificity of 0.41 (95% CI, 0.39-0.60), and STA Liatest D-dimer had a sensitivity of 0.98 (95% CI, 0.93-0.99) and a specificity of 0.40 (95% CI, 0.32-0.49). The pooled estimates for D-dimer sensitivity and specificity were 0.97 (95% CI, 0.96-0.98) and 0.411 (95% CI, 0.36-0.46), respectively. Figure 2 shows the forest plot displaying the sensitivity and specificity from individual studies and the pooled estimates for all D-dimer assays. Figures 3-5 show the forest plots displaying sensitivity and specificity from individual studies for specific assays.

Figure 2.

Forest plot for all D-dimer assays.

Figure 2.

Forest plot for all D-dimer assays.

Close modal
Figure 3.

Forest plot for Vidas D-dimer assay.

Figure 3.

Forest plot for Vidas D-dimer assay.

Close modal
Figure 4.

Forest plot for Tina-quant D-dimer assay.

Figure 4.

Forest plot for Tina-quant D-dimer assay.

Close modal
Figure 5.

Forest plot for STA Liatest D-dimer assay.

Figure 5.

Forest plot for STA Liatest D-dimer assay.

Close modal

D-dimer results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-negative results and a high proportion of false-positive results (>5%). Overall, the test was shown to be highly sensitive but had low specificity. The certainty of evidence was moderate. Table 2 shows the summary of findings.

Table 2.

D-dimer test accuracy in a low-prevalence population

Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 49 (48-49) 22 849 (34) ⨁⨁⨁◯ MODERATE§ 
False negatives 1 (1-2) 
True negatives 389 (352-437) 22 849 (34) ⨁⨁⨁◯ MODERATE§ 
False positives 561 (513-608) 
Inconclusive test results 22 849 (34) — 
Complications arising from the diagnostic test Not reported 
Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 49 (48-49) 22 849 (34) ⨁⨁⨁◯ MODERATE§ 
False negatives 1 (1-2) 
True negatives 389 (352-437) 22 849 (34) ⨁⨁⨁◯ MODERATE§ 
False positives 561 (513-608) 
Inconclusive test results 22 849 (34) — 
Complications arising from the diagnostic test Not reported 

Patient or population: patients with suspected PE. Setting: inpatient and outpatient. Pooled sensitivity: 0.97 (95% CI, 0.96-0.98). Pooled specificity: 0.41 (95% CI, 0.36-0.46). An interactive summary of findings is available at https://gdt.gradepro.org/presentations/#/isof/isof_4a1a37bd-1b30-40b7-adea-d5214ffb73c2-1581444096033?_k=f5c4gy.

GRADE, Grading of Recommendations Assessment, Development and Evaluation.

*

Ceriani E, et al. J Thromb Haemost. 2010;8(5):957. Pooled prevalence of PE with low PTP in North American studies 6.5% (5% used in table).

Disease prevalence applies to the index test in each pathway. Prevalence applied to the accuracy of each subsequent test depends on the result of the previous test in the pathway.

Certainty of evidence not downgraded for risk of bias, although few studies had a combination of reference standards that were judged to be acceptable by a panel of clinical experts.

§

Although there was inconsistency noted for sensitivity, it was judged as not serious and we did not downgrade the certainty of evidence. Certainty of evidence was downgraded for serious unexplained inconsistency in specificity, with a range from 12.8% to 64%.

Age-adjusted D-dimer

Test accuracy data for age-adjusted D-dimer were pooled from 1 study, with a total of 2885 participants.43  We did not include retrospective validation studies. The pooled estimates for age adjusted D-dimer sensitivity and specificity were 0.99 (95% CI, 0.98-1.00) and 0.47 (95% CI, 0.45-0.49), respectively. Figure 2 shows the forest plot displaying the sensitivity and specificity from individual studies and the pooled estimates.

Age-adjusted D-dimer results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-negative results and a high proportion of false-positive results (>5%). Overall, the test was shown to be highly sensitive but had low specificity. The certainty of evidence was high. Table 3 shows the summary of findings.

Table 3.

Age-adjusted D-dimer test accuracy in a low-prevalence population

Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 50 (49-50) 2885 (1) ⨁⨁⨁⨁ HIGH 
False negatives 0 (0-1) 
True negatives 446 (428-465) 2885 (1) ⨁⨁⨁⨁ HIGH 
False positives 504 (485-522) 
Inconclusive test results 2885 (1) — 
Complications arising from the diagnostic test Not reported 
Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 50 (49-50) 2885 (1) ⨁⨁⨁⨁ HIGH 
False negatives 0 (0-1) 
True negatives 446 (428-465) 2885 (1) ⨁⨁⨁⨁ HIGH 
False positives 504 (485-522) 
Inconclusive test results 2885 (1) — 
Complications arising from the diagnostic test Not reported 

Patient or population: patients with suspected PE. Setting: inpatient and outpatient. Pooled sensitivity: 0.99 (95% CI, 0.98-1.00). Pooled specificity: 0.47 (95% CI, 0.45-0.49). An interactive summary of findings is available at https://gdt.gradepro.org/presentations/#/isof/isof_a6f96835-4b9e-4342-b4ab-7dae1b5c9ead-1569977909216?_k=46z8fa.

*

Pooled prevalence of PE with low PTP in North American studies 6.5% (5% used in table).18 

Disease prevalence applies to the index test in each pathway. Prevalence applied to the accuracy of each subsequent test depends on the result of the previous test in the pathway.

Certainty of evidence not downgraded for imprecision given the large population size, though only 1 prospective age-adjusted D-dimer study was identified for analysis.

CTPA

Test accuracy data for CTPA were pooled from 16 studies, with a total of 4392 participants.26,28,35,38,42,43,53-62  The pooled estimates for CTPA sensitivity and specificity were 0.94 (95% CI, 0.89-0.97) and 0.98 (95% CI, 0.97-0.99), respectively. Figure 6 shows the forest plot displaying the sensitivity and specificity from individual studies and the pooled estimates.

Figure 6.

Forest plot for CTPA.

Figure 6.

Forest plot for CTPA.

Close modal

CTPA results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-negative and false-positive results. Overall, the test was shown to be highly sensitive and specific and the certainty of evidence was moderate. Table 4 shows the summary of findings.

Table 4.

CTPA test accuracy in a low-prevalence population

Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 47 (45-49) 4392 (16) ⨁⨁⨁◯ MODERATE§ 
False negatives 3 (1-5) 
True negatives 931 (922-941) 4392 (16) ⨁⨁⨁◯ MODERATE§ 
False positives 19 (9-28) 
Inconclusive test results 115 4392 (16) — 
Complications arising from the diagnostic test Not reported 
Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 47 (45-49) 4392 (16) ⨁⨁⨁◯ MODERATE§ 
False negatives 3 (1-5) 
True negatives 931 (922-941) 4392 (16) ⨁⨁⨁◯ MODERATE§ 
False positives 19 (9-28) 
Inconclusive test results 115 4392 (16) — 
Complications arising from the diagnostic test Not reported 

Patient or population: patients with suspected PE. Setting: inpatient and outpatient. Pooled sensitivity: 0.94 (95% CI, 0.89-0.97). Pooled specificity: 0.98 (95% CI, 0.97-0.99). An interactive summary of findings is available at: https://gdt.gradepro.org/presentations/#/isof/isof_1841b2e2-df16-431d-b809-de3913a3b6f5-1569994386148?_k=w5d920.

*

Pooled prevalence of PE with low PTP in North American studies 6.5% (5% used in table).18 

Disease prevalence applies to the index test in each pathway. Prevalence applied to the accuracy of each subsequent test depends on the result of the previous test in the pathway.

Certainty of evidence not downgraded for risk of bias, although few studies had a combination of reference standards that were judged to be acceptable by a panel of clinical experts.

§

Certainty of evidence was downgraded for serious unexplained inconsistency in sensitivity, with a range from 63% to 99.2%. There was inconsistency also noted for specificity, but it was judged as not serious and we did not to downgrade the certainty of evidence.

Compression ultrasound

Test accuracy data for proximal vein CUS (ie, proximal to the calf veins [trifurcation veins and higher]) were pooled from 7 studies, with a total of 1715 participants.42,63-68  The pooled estimates for CUS sensitivity and specificity were 0.49 (95% CI, 0.31-0.66) and 0.96 (95% CI, 0.95-0.98), respectively. Figure 7 shows the forest plot displaying the sensitivity and specificity from individual studies and the pooled estimates.

Figure 7.

Forest plot for CUS.

Figure 7.

Forest plot for CUS.

Close modal

CUS results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-positive results and a high proportion of false-negative results (>5%). Overall, the test was shown to be highly specific but had low sensitivity. The certainty of evidence was low. Table 5 shows the summary of findings.

Table 5.

Proximal CUS sensitivity and specificity in a low-prevalence population

Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 25 (16-33) 1715 (7) ⨁⨁◯◯ LOW§ 
False negatives 25 (17-34) 
True negatives 912 (903-931) 1715 (7) ⨁⨁◯◯ LOW§ 
False positives 38 (19-47) 
Inconclusive test results 1715 (7) — 
Complications arising from the diagnostic test Not reported 
Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 5%* in patients with suspected PE
True positives 25 (16-33) 1715 (7) ⨁⨁◯◯ LOW§ 
False negatives 25 (17-34) 
True negatives 912 (903-931) 1715 (7) ⨁⨁◯◯ LOW§ 
False positives 38 (19-47) 
Inconclusive test results 1715 (7) — 
Complications arising from the diagnostic test Not reported 

Patient or population: patients with suspected PE. Setting: inpatient and outpatient. Pooled sensitivity: 0.49 (95% CI, 0.31-0.66). Pooled specificity: 0.96 (95% CI, 0.95-0.98). An interactive summary of findings is available at: https://gdt.gradepro.org/presentations/#/isof/isof_4b33e40d-b17a-4359-964b-51aca44d75e4-1569994797123?_k=cykq2y.

*

Pooled prevalence of PE with low PTP in North American studies 6.5% (5% used in table).18 

Disease prevalence applies to the index test in each pathway. Prevalence applied to the accuracy of each subsequent test depends on the result of the previous test in the pathway.

Certainty of evidence not downgraded for risk of bias, although few studies had a combination of reference standards that were judged to be acceptable by a panel of clinical experts.

§

Certainty of evidence was downgraded for serious unexplained inconsistency in sensitivity, with a range from 18.4% to 96.7%. There was inconsistency also noted for specificity, but it was judged as not serious and we did not to downgrade the certainty of evidence.

V/Q scan

Test accuracy data for V/Q scans were pooled from 13 studies, with a total of 3994 participants.26,53,57,67-76  Three variations of pooled estimates for sensitivity and specificity of V/Q scan were carried out.

V/Q scans for which high probability scans were considered positive and low/nondiagnostic/normal scans were considered negative had a sensitivity and specificity of 0.58 (95% CI, 0.50-0.66) and 0.98 (95% CI, 0.96-0.99), respectively. Figure 8 shows the forest plot displaying the sensitivity and specificity from individual studies and the pooled estimates. V/Q scan results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-positive results and a high proportion of false-negative results (>5%). Overall, the test was shown to be highly specific but had low sensitivity. The certainty of evidence was moderate. Table 6A shows the summary of findings.

Figure 8.

Forest plot for VQ1: high-probability scans considered positive and low/nondiagnostic/normal scans considered negative.

Figure 8.

Forest plot for VQ1: high-probability scans considered positive and low/nondiagnostic/normal scans considered negative.

Close modal
Table 6.

Ventilation/perfusion scan sensitivity and specificity for a low-prevalence population

No. of results per 1000 patients tested (95% CI)
Prevalence 5%* in patients with suspected PENo. of participants (studies)Certainty of the evidence (GRADE)
Test resultABCABCABC
True positives 29 (25-33) 49 (48-50) 48 (46-49) 3994 (13) 3994 (13) 1799 (13) ⨁⨁⨁◯ MODERATE§ ⨁⨁⨁◯ MODERATE|| ⨁⨁⨁⨁ HIGH|| 
False negatives 21 (17-25) 1 (0-2) 2 (1-4) 
True negatives 931 (912-941) 342 (257-428) 903 (845-931) 3994 (13) 3994 (13) 1799 (13) ⨁⨁⨁◯ MODERATE§ ⨁⨁⨁◯ MODERATE|| ⨁⨁⨁⨁ HIGH|| 
False positives 19 (9-38) 608 (522-693) 47 (19-105) 
Inconclusive test results 1849 1849 3994 (13) 3994 (13) 1799 (13)  
Complications arising from the diagnostic test Not reported 
No. of results per 1000 patients tested (95% CI)
Prevalence 5%* in patients with suspected PENo. of participants (studies)Certainty of the evidence (GRADE)
Test resultABCABCABC
True positives 29 (25-33) 49 (48-50) 48 (46-49) 3994 (13) 3994 (13) 1799 (13) ⨁⨁⨁◯ MODERATE§ ⨁⨁⨁◯ MODERATE|| ⨁⨁⨁⨁ HIGH|| 
False negatives 21 (17-25) 1 (0-2) 2 (1-4) 
True negatives 931 (912-941) 342 (257-428) 903 (845-931) 3994 (13) 3994 (13) 1799 (13) ⨁⨁⨁◯ MODERATE§ ⨁⨁⨁◯ MODERATE|| ⨁⨁⨁⨁ HIGH|| 
False positives 19 (9-38) 608 (522-693) 47 (19-105) 
Inconclusive test results 1849 1849 3994 (13) 3994 (13) 1799 (13)  
Complications arising from the diagnostic test Not reported 

Patient or population: patients with suspected PE. Setting: inpatient and outpatient. A: V/Q scan with high probability scan interpreted as positive, normal/low/nondiagnostic scan as negative. An interactive summary of findings is available at: https://gdt.gradepro.org/presentations/#/isof/isof_88bb7995-dec1-4116-9b07-a2f15691c2c4-1570046058781?_k=fmsw16. Pooled sensitivity of A: 0.58 (95% CI, 0.50-0.66); pooled specificity: 0.98 (95% CI, 0.96-0.99). B: V/Q scan with high/nondiagnostic/low probability scan interpreted as positive, normal scan as negative. An interactive summary of findings is available at: https://gdt.gradepro.org/presentations/#/isof/isof_2564a7dd-52d5-442b-bfee-0d6495de7cfc-1570045676857?_k=pihtmp. Pooled sensitivity of B: 0.98 (95% CI, 0.95-0.99); pooled specificity: 0.36 (95% CI, 0.27-0.45). C: V/Q scan with high probability scan as positive, normal scan as negative. An interactive summary of findings is available at: https://gdt.gradepro.org/presentations/#/isof/isof_3f842c9a-15d3-4b16-8ed5-0011f3157c53-1570045878061?_k=vgsgvi.

*

Pooled prevalence of PE with low PTP in North American studies 6.5% (5% used in table).18 

Disease prevalence applies to the index test in each pathway. Prevalence applied to the accuracy of each subsequent test depends on the result of the previous test in the pathway.

Certainty of evidence not downgraded for risk of bias, although few studies had a combination of reference standards that were judged to be acceptable by a panel of clinical experts.

§

Certainty of evidence was downgraded for serious unexplained inconsistency in sensitivity, with a range from 13.9% to 84.6%. Minor inconsistency for specificity noted but judged to be insufficient to downgrade the certainty of evidence.

||

Although there was inconsistency noted for sensitivity, it was judged as not serious and we did not downgrade the certainty of evidence. Certainty of evidence was downgraded for serious unexplained inconsistency in specificity, with a range from 10.9% to 81.8%.

Although there was inconsistency noted for sensitivity, it was judged as not serious and we did not downgrade the certainty of evidence. There was inconsistency also noted for specificity, but it was judged as not serious and we did not to downgrade the certainty of evidence.

V/Q scans with high/nondiagnostic/low probability scans considered as positive and normal scans as negative had a sensitivity and specificity of 0.98 (95% CI, 0.95-0.99) and 0.36 (95% CI, 0.27-0.45), respectively. Figure 9 shows the forest plot displaying the sensitivity and specificity from individual studies and the pooled estimates. V/Q scan results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-negative results and a high proportion of false-positive results (>5%). Overall, the test was shown to be highly sensitive but had low specificity. The certainty of evidence was moderate. Table 6B shows the summary of findings.

Figure 9.

Forest plot for VQ2: high/nondiagnostic/low probability scans considered as positive and normal scans as negative.

Figure 9.

Forest plot for VQ2: high/nondiagnostic/low probability scans considered as positive and normal scans as negative.

Close modal

V/Q scans for which high-probability scans were considered positive and normal scans as negative had a sensitivity and specificity of 0.96 (95% CI, 0.91-0.98) and 0.95 (95% CI, 0.89-0.98), respectively. Figure 10 shows the forest plot displaying the sensitivity and specificity from individual studies and the pooled estimates. V/Q scan results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-negative and false-positive results. Overall, the test was shown to be highly sensitive and specific and the certainty of evidence was moderate. The certainty of evidence was high. Table 6C shows the summary of findings.

Figure 10.

Forest plot for VQ3: high-probability scans considered positive and normal scans considered negative.

Figure 10.

Forest plot for VQ3: high-probability scans considered positive and normal scans considered negative.

Close modal

Recurrent PE

Test accuracy data for recurrent PE were pooled from 3 studies.77-79 Tables 7 and 8 show the modeled data findings for this comparison.

Table 7.

Recurrent PE: D-dimer for patients with low clinical probability, CTPA for patients with low clinical probability and positive D-dimer, or high clinical probability sensitivity and specificity

Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 30%* in patients suspected of having PEPrevalence 40%†§ in patients suspected of having PE
True positives 291 (282-294) 388 (376-392) 992 (3) ⨁⨁⨁◯ MODERATE|| 
False negatives 9 (6-18) 12 (8-24) 
True negatives 700 (693-700) 600 (594-600) 992 (3) ⨁⨁⨁◯ MODERATE|| 
False positives 0 (0-7) 0 (0-6) 
Inconclusive test results 992 (3) — 
Complications arising from the diagnostic test Not reported 
Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 30%* in patients suspected of having PEPrevalence 40%†§ in patients suspected of having PE
True positives 291 (282-294) 388 (376-392) 992 (3) ⨁⨁⨁◯ MODERATE|| 
False negatives 9 (6-18) 12 (8-24) 
True negatives 700 (693-700) 600 (594-600) 992 (3) ⨁⨁⨁◯ MODERATE|| 
False positives 0 (0-7) 0 (0-6) 
Inconclusive test results 992 (3) — 
Complications arising from the diagnostic test Not reported 

Patient or population: patients with suspected recurrent PE. Setting: inpatient and outpatient. Pooled sensitivity: 0.97 (95% CI, 0.94-0.98). Pooled specificity: 1.00 (95% CI, 0.99-1.00). An interactive summary of findings is available at: https://gdt.gradepro.org/presentations/#/isof/isof_e7c58633-0d3e-4209-9a2f-5f072eaca759-1569995555070?_k=3k1k5o.

*

Data from Mos et al.78 

†Data from Nijkeuter et al.79 

Disease prevalence applies to the index test in each pathway. Prevalence applied to the accuracy of the subsequent tests depends on the result of the previous test in the pathway.

§

Data from Le Gal et al.77 

||

Certainty of evidence was downgraded for imprecision given the small population size from the 3 recurrent PE study identified for analysis.

Table 8.

D-dimer for recurrent PE sensitivity and specificity

Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 30%* in patients suspected of having PEPrevalence 40%§ in patients suspected of having PE
True positives 300 (291-300) 400 (388-400) 304 (1) ⨁⨁◯◯ LOW|| 
False negatives 0 (0-9) 0 (0-12) 
True negatives 189 (147-238) 162 (126-204) 304 (1) ⨁⨁◯◯ LOW|| 
False positives 511 (462-553) 438 (396-474) 
Inconclusive test results 304 (1)  
Complications arising from the diagnostic test Not reported 
Test resultNo. of results per 1000 patients tested (95% CI)No. of participants (studies)Certainty of the evidence (GRADE)
Prevalence 30%* in patients suspected of having PEPrevalence 40%§ in patients suspected of having PE
True positives 300 (291-300) 400 (388-400) 304 (1) ⨁⨁◯◯ LOW|| 
False negatives 0 (0-9) 0 (0-12) 
True negatives 189 (147-238) 162 (126-204) 304 (1) ⨁⨁◯◯ LOW|| 
False positives 511 (462-553) 438 (396-474) 
Inconclusive test results 304 (1)  
Complications arising from the diagnostic test Not reported 

Patient or population: patients with suspected recurrent pulmonary embolism. Setting: inpatient and outpatient. Pooled sensitivity: 1.00 (95% CI, 0.97-1.00). Pooled specificity: 0.27 (95% CI, 0.21-0.34). An interactive summary of findings is available at: https://gdt.gradepro.org/presentations/#/isof/isof_16692888-165a-4eaa-ac25-6823e63d0aff-1569995266014?_k=4hew36.

*

Data from Mos et al.78 

Data from Nijkeuter et al.79 

Disease prevalence applies to the index test in each pathway. Prevalence applied to the accuracy of the subsequent tests depends on the result of the previous test in the pathway.

§

Data from Le Gal et al.77 

||

Certainty of evidence was downgraded for imprecision given the small population size from the 1 recurrent PE study identified for analysis.

Certainty of evidence was downgraded for risk of bias from a secondary analysis of 2 prospective multicenter studies with a mixed population of recurrent and first-time PE patients.

For the sequence of D-dimer testing for low clinical PTP patients, CTPA testing for low clinical PTP patients with positive D-dimer or high clinical PTP patients, the pooled estimates for sensitivity and specificity were 0.97 (95% CI, 0.94-0.98) and 1.00 (95% CI, 0.99-1.00), respectively. This diagnostic algorithm was illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-negative and false-positive results. Overall, the test was shown to be highly sensitive and specific and the certainty of evidence was moderate. The certainty of evidence was moderate. Table 7 shows the summary of findings.

For D-dimer alone, the pooled estimates for sensitivity and specificity were 1.00 (95% CI, 0.97-1.00) and 0.27 (95% CI, 0.21-0.34), respectively. The certainty of evidence was low for true positives, true negatives, false positives, and false negatives. D-dimer results were illustrated for 1000 patients from a low-prevalence population undergoing the test, and absolute differences indicate a low (<5%) proportion of false-negative results and a high proportion of false-positive results (>5%). Overall, the test was shown to be highly sensitive but had low specificity. The certainty of evidence was low. Table 8 shows the summary of findings.

This review presents pooled estimates of test accuracy for commonly available diagnostic methods for PE. The certainty of evidence ranged from low to high for test accuracy. The only diagnostic test with a low certainty of evidence was CUS, whereas the other tests had moderate to high certainty of evidence. Of the evaluated tests, D-dimer had the highest sensitivity at 0.97 (95% CI, 0.96-0.98), with age-adjusted D-dimer having an even higher sensitivity of 0.99 (95% CI, 0.98-1.00). CTPA and V/Q scans (high probability scan as a positive and low/nondiagnostic/normal scan as negative) both had the highest specificity at 0.98 (95% CI, 0.97-0.99) and 0.98 (95% CI, 0.96-0.99), respectively. The sensitivity and specificity results obtained in this systematic review were used in a model to determine the effects of different strategies to diagnose patients suspected of having PE. The modeling results were used to make evidence-based recommendations on diagnostic test approaches to PE in the American Society of Hematology evidence-based guidelines.13 

This review has several strengths. The comprehensive and systematic approach for identifying studies makes it unlikely that relevant studies were missed. We also attempted to include studies with insufficient information to abstract test accuracy by contacting researchers of those studies to obtain primary data. For example, in The Christopher Study,80  we were unable to abstract the patients that were low PTP with a positive D-dimer who underwent a CTPA from the high PTP patients that went straight to CTPA. We were unable to obtain the primary data; therefore, the study was excluded. Several post hoc analyses papers had the missing data, so these were included for analysis but the original study was excluded to avoid duplication. Additionally, we did not limit our review by language and translated articles that were not published in English. Finally, we assessed the certainty of evidence in this area and identified sources of bias.

There are a few limitations of the present review. The high sensitivity of age-adjusted D-dimer is limited by the fact that only 1 study evaluating age-adjusted D-dimer prospectively was identified for analysis. We excluded many emerging and promising modalities such as magnetic resonance imaging (and V/Q single-photon emission CT) because limited data are available. In addition, many of the studies that were included did not have an actual reference test. Occasionally, studies used follow up (eg, 3 months, 6 months) as a reference standard to testing, which was deemed acceptable by the panel. Clinically insignificant PE may be missed with follow-up as a reference, but this was acceptable because it determines the performance of the test in a clinically significant setting. Last, the diagnostic test accuracy estimates were determined for a test done in a standalone manner, and we did not consider combinations of tests in a pathway for establishing a diagnosis of PE. This may be required, for example, in patients who have a low PTP but have a positive D-dimer. The pooled sensitivity and specificity estimates of the tests from this review only apply when the test is performed alone, which may be applicable in certain populations. For example, compression ultrasound is rarely used as a standalone test for the diagnosis of PE; however, certain clinical conditions may necessitate the use of compression ultrasound alone (eg, patients who cannot initially undergo any direct lung imaging because of renal failure or pregnancy). The results in this review can be used to model various diagnostic strategies to inform clinical decision-making. Ultimately, the diagnostic tests will be used in a strategic approach based on clinical pretest probability and with consideration of availability, cost, and patient and provider values and preferences.

In conclusion, this systematic review synthesizes and evaluates the accuracy of commonly used tests for the diagnosis of PE. Estimates of sensitivity and specificity from this review were used to model diagnostic strategies and inform evidence-based recommendations for a clinical practice guideline.13  The prevalence or pretest probability for PE along with the sensitivity and specificity estimates will influence clinical decision-making and patient management.

The systematic review team would like to acknowledge the Canadian Agency for Drugs and Technologies in Health team for their assistance with data management and organization of the manuscript.

This systematic review was conducted to support the development of the American Society of Hematology (ASH) 2018 guidelines for management of venous thromboembolism: diagnosis of venous thromboembolism. The entire guideline development process was funded by ASH. Through the McMaster GRADE Center, some researchers received salary (Parth Patel, Payal Patel, C.B., M.B., W.W., H.B., and J.V.) or grant support (R.A.M. and H.J.S.); others participated to fulfill requirements of an academic degree or program or volunteered their time.

Contribution: Parth Patel contributed to study design, search strategy, study selection, data extraction, statistical analysis, and drafting the report; Parth Patel, M.B., C.B., H.B., R.A.M., M.A.K., N.M.H., Y.N.A.J., and Payal Patel contributed to study design, study selection, data extraction, statistical analysis, and critical revision of the report; J.V., D.W., H.A., M.T., M.B., W.B., R. Khatib, R. Kehar, R.P., A.S., and A.M. contributed to study selection and data extraction; and W.W., W.L., G.L.G., S.M.B., L.B.H., J.K., E.L., M.R., H.J.S., and R.A.M. contributed to the study design, interpretation of the results, and critical revision of the report.

Conflict-of-interest disclosure: The authors declare no competing financial interests.

Correspondence: Reem A. Mustafa, Division of Nephrology and Hypertension, Department of Medicine, University of Kansas Medical Center, 3901 Rainbow Blvd, MS3002, Kansas City, KS 66160; e-mail: ramustafa@gmail.com.

1.
Wiener
RS
,
Schwartz
LM
,
Woloshin
S
.
Time trends in pulmonary embolism in the United States: evidence of overdiagnosis
.
Arch Intern Med
.
2011
;
171
(
9
):
831
-
837
.
2.
Kröger
K
,
Küpper-Nybelen
J
,
Moerchel
C
,
Moysidis
T
,
Kienitz
C
,
Schubert
I
.
Prevalence and economic burden of pulmonary embolism in Germany
.
Vasc Med
.
2012
;
17
(
5
):
303
-
309
.
3.
Huang
W
,
Goldberg
RJ
,
Anderson
FA
,
Kiefe
CI
,
Spencer
FA
.
Secular trends in occurrence of acute venous thromboembolism: the Worcester VTE study (1985-2009)
.
Am J Med
.
2014
;
127
(
9
):
829
-
39.e5
.
4.
Goldacre
MJ
,
Roberts
S
,
Yeates
D
,
Griffith
M
.
Hospital admission and mortality rates for venous thromboembolism in Oxford region, UK, 1975-98
.
Lancet
.
2000
;
355
(
9219
):
1968
-
1969
.
5.
Martinez
C
,
Cohen
AT
,
Bamber
L
,
Rietbrock
S
.
Epidemiology of first and recurrent venous thromboembolism: a population-based cohort study in patients without active cancer
.
Thromb Haemost
.
2014
;
112
(
2
):
255
-
263
.
6.
Alotaibi
GS
,
Wu
C
,
Senthilselvan
A
,
McMurtry
MS
.
Secular trends in incidence and mortality of acute venous thromboembolism: the AB-VTE Population-Based Study
.
Am J Med
.
2016
;
129
(
8
):
879.e19
-
879.e25
.
7.
Konstantinides
SV
.
Trends in incidence versus case fatality rates of pulmonary embolism: Good news or bad news?
Thromb Haemost
.
2016
;
115
(
2
):
233
-
235
.
8.
Horlander
KT
,
Mannino
DM
,
Leeper
KV
.
Pulmonary embolism mortality in the United States, 1979-1998: an analysis using multiple-cause mortality data
.
Arch Intern Med
.
2003
;
163
(
14
):
1711
-
1717
.
9.
The Surgeon General's Call to Action to Prevent Deep Vein Thrombosis and Pulmonary Embolism. Rockville, MD: Office of the Surgeon General, National Heart, Lung, and Blood Institute; 2008
.
10.
Cohen
AT
,
Agnelli
G
,
Anderson
FA
, et al;
VTE Impact Assessment Group in Europe (VITAE)
.
Venous thromboembolism (VTE) in Europe. The number of VTE events and associated morbidity and mortality
.
Thromb Haemost
.
2007
;
98
(
4
):
756
-
764
.
11.
Warren
DJ
,
Matthews
S
.
Pulmonary embolism: investigation of the clinically assessed intermediate risk subgroup
.
Br J Radiol
.
2012
;
85
(
1009
):
37
-
43
.
12.
Bates
SM
,
Takach Lapner
S
,
Douketis
JD
, et al
.
Rapid quantitative D-dimer to exclude pulmonary embolism: a prospective cohort management study
.
J Thromb Haemost
.
2016
;
14
(
3
):
504
-
509
.
13.
Lim
W
,
Le Gal
G
,
Bates
SM
, et al
.
American Society of Hematology 2018 guidelines for management of venous thromboembolism: diagnosis of venous thromboembolism
.
Blood Adv
.
2018
;
2
(
22
):
3226
-
3256
.
14.
Whiting
PF
,
Rutjes
AWS
,
Westwood
ME
, et al;
QUADAS-2 Group
.
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
.
Ann Intern Med
.
2011
;
155
(
8
):
529
-
536
.
15.
Schünemann
HJ
,
Oxman
AD
,
Brozek
J
, et al;
GRADE Working Group
.
Grading quality of evidence and strength of recommendations for diagnostic tests and strategies [published correction appears in BMJ. 2008;336(7654)]
.
BMJ
.
2008
;
336
(
7653
):
1106
-
1110
.
16.
Schünemann
HJ
,
Oxman
AD
,
Brozek
J
, et al
.
GRADE: assessing the quality of evidence for diagnostic recommendations
.
ACP J Club
.
2008
;
149
(
6
):
2
.
17.
Macaskill
P
,
Gatsonis
C
,
Deeks
J
,
Harbord
R
,
Takwoingi
Y
.
Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. Version 09 0. London: The Cochrane Collaboration; 2010
.
18.
Ceriani
E
,
Combescure
C
,
Le Gal
G
, et al
.
Clinical prediction rules for pulmonary embolism: a systematic review and meta-analysis
.
J Thromb Haemost
.
2010
;
8
(
5
):
957
-
970
.
19.
Abcarian
PW
,
Sweet
JD
,
Watabe
JT
,
Yoon
HC
.
Role of a quantitative D-dimer assay in determining the need for CT angiography of acute pulmonary embolism
.
AJR Am J Roentgenol
.
2004
;
182
(
6
):
1377
-
1381
.
20.
Bosson
JL
,
Barro
C
,
Satger
B
,
Carpentier
PH
,
Polack
B
,
Pernod
G
.
Quantitative high D-dimer value is predictive of pulmonary embolism occurrence independently of clinical score in a well-defined low risk factor population
.
J Thromb Haemost
.
2005
;
3
(
1
):
93
-
99
.
21.
de Moerloose
P
,
Desmarais
S
,
Bounameaux
H
, et al
.
Contribution of a new, rapid, individual and quantitative automated D-dimer ELISA to exclude pulmonary embolism
.
Thromb Haemost
.
1996
;
75
(
1
):
11
-
13
.
22.
de Monyé
W
,
Sanson
BJ
,
Büller
HR
,
Pattynama
PM
,
Huisman
MV
;
ANTELOPE Study Group
.
The performance of two rapid quantitative D-dimer assays in 287 patients with clinically suspected pulmonary embolism
.
Thromb Res
.
2002
;
107
(
6
):
283
-
286
.
23.
den Exter
PL
,
van Es
J
,
Erkens
PM
, et al
.
Impact of delay in clinical presentation on the diagnostic management and prognosis of patients with suspected pulmonary embolism
.
Am J Respir Crit Care Med
.
2013
;
187
(
12
):
1369
-
1373
.
24.
Di Nisio
M
,
Sohne
M
,
Kamphuisen
PW
,
Büller
HR
.
D-Dimer test in cancer patients with suspected acute pulmonary embolism
.
J Thromb Haemost
.
2005
;
3
(
6
):
1239
-
1242
.
25.
Dunn
KL
,
Wolf
JP
,
Dorfman
DM
,
Fitzpatrick
P
,
Baker
JL
,
Goldhaber
SZ
.
Normal D-dimer levels in emergency department patients suspected of acute pulmonary embolism
.
J Am Coll Cardiol
.
2002
;
40
(
8
):
1475
-
1478
.
26.
Elias
A
,
Colombier
D
,
Victor
G
, et al
.
Diagnostic performance of complete lower limb venous ultrasound in patients with clinically suspected acute pulmonary embolism
.
Thromb Haemost
.
2004
;
91
(
1
):
187
-
195
.
27.
Emet
M
,
Ozucelik
DN
,
Sahin
M
,
Oran
M
,
Sivri
B
.
Computed tomography pulmonary angiography in the diagnosis of acute pulmonary embolism in the emergency department
.
Adv Ther
.
2007
;
24
(
6
):
1173
-
1180
.
28.
Eng
CW
,
Wansaicheong
G
,
Goh
SK
,
Earnest
A
,
Sum
C
.
Exclusion of acute pulmonary embolism: computed tomography pulmonary angiogram or D-dimer?
Singapore Med J
.
2009
;
50
(
4
):
403
-
406
.
29.
Friera-Reyes
A
,
Caballero
P
,
Ruiz-Giménez
N
, et al;
Grupo de Estudio de Enfermedad Tromboembólica Venosa
.
[Usefulness of fast ELISA determination of D-dimer levels for diagnosing pulmonary embolism in an emergency room]
.
Arch Bronconeumol
.
2005
;
41
(
9
):
499
-
504
.
30.
Froehling
DA
,
Daniels
PR
,
Swensen
SJ
, et al
.
Evaluation of a quantitative D-dimer latex immunoassay for acute pulmonary embolism diagnosed by computed tomographic angiography
.
Mayo Clin Proc
.
2007
;
82
(
5
):
556
-
560
.
31.
Ghanima
W
,
Abdelnoor
M
,
Mowinckel
MC
,
Sandset
PM
.
The performance of STA-Liatest D-dimer assay in out-patients with suspected pulmonary embolism
.
Br J Haematol
.
2006
;
132
(
2
):
210
-
215
.
32.
Goekoop
RJ
,
Steeghs
N
,
Niessen
RW
, et al
.
Simple and safe exclusion of pulmonary embolism in outpatients using quantitative D-dimer and Wells’ simplified decision rule
.
Thromb Haemost
.
2007
;
97
(
1
):
146
-
150
.
33.
Leclercq
MG
,
Lutisan
JG
,
van Marwijk Kooy
M
, et al
.
Ruling out clinically suspected pulmonary embolism by assessment of clinical probability and D-dimer levels: a management study
.
Thromb Haemost
.
2003
;
89
(
1
):
97
-
103
.
34.
Oger
E
,
Leroyer
C
,
Bressollette
L
, et al
.
Evaluation of a new, rapid, and quantitative D-Dimer test in patients with suspected pulmonary embolism
.
Am J Respir Crit Care Med
.
1998
;
158
(
1
):
65
-
70
.
35.
Pacouret
G
,
Marie
O
,
Alison
D
, et al
.
[Association of D-dimer and helicoidal thoracic scanner for diagnosis of pulmonary embolism. Prospective study of 106 ambulatory patients]
.
Presse Med
.
2002
;
31
(
1 Pt 1
):
13
-
18
.
36.
Palud
L
,
Laurent
M
,
Guéret
P
, et al
.
[Value of the association of D-dimer measurement and the evaluation of clinical probability in a non-invasive diagnostic strategy of pulmonary embolism]
.
Arch Mal Coeur Vaiss
.
2004
;
97
(
2
):
93
-
99
.
37.
Parent
F
,
Maître
S
,
Meyer
G
, et al
.
Diagnostic value of D-dimer in patients with suspected pulmonary embolism: results from a multicentre outcome study
.
Thromb Res
.
2007
;
120
(
2
):
195
-
200
.
38.
Perrier
A
,
Roy
P-M
,
Sanchez
O
, et al
.
Multidetector-row computed tomography in suspected pulmonary embolism
.
N Engl J Med
.
2005
;
352
(
17
):
1760
-
1768
.
39.
Perrier
A
,
Desmarais
S
,
Miron
MJ
, et al
.
Non-invasive diagnosis of venous thromboembolism in outpatients
.
Lancet
.
1999
;
353
(
9148
):
190
-
195
.
40.
Perrier
A
,
Roy
PM
,
Aujesky
D
, et al
.
Diagnosing pulmonary embolism in outpatients with clinical assessment, D-dimer measurement, venous ultrasound, and helical computed tomography: a multicenter management study
.
Am J Med
.
2004
;
116
(
5
):
291
-
299
.
41.
Quinn
DA
,
Fogel
RB
,
Smith
CD
, et al
.
D-dimers in the diagnosis of pulmonary embolism
.
Am J Respir Crit Care Med
.
1999
;
159
(
5 Pt 1
):
1445
-
1449
.
42.
Righini
M
,
Le Gal
G
,
Aujesky
D
, et al
.
Diagnosis of pulmonary embolism by multidetector CT alone or combined with venous ultrasonography of the leg: a randomised non-inferiority trial
.
Lancet
.
2008
;
371
(
9621
):
1343
-
1352
.
43.
Righini
M
,
Van Es
J
,
Den Exter
PL
, et al
.
Age-adjusted D-dimer cutoff levels to rule out pulmonary embolism: the ADJUST-PE study
.
JAMA
.
2014
;
311
(
11
):
1117
-
1124
.
44.
Sijens
PE
,
van Ingen
HE
,
van Beek
EJ
,
Berghout
A
,
Oudkerk
M
.
Rapid ELISA assay for plasma D-dimer in the diagnosis of segmental and subsegmental pulmonary embolism. A comparison with pulmonary angiography
.
Thromb Haemost
.
2000
;
84
(
2
):
156
-
159
.
45.
Söderberg
M
,
Brohult
J
,
Jorfeldt
L
,
Lärfars
G
.
The use of D-dimer testing and Wells score in patients with high probability for acute pulmonary embolism
.
J Eval Clin Pract
.
2009
;
15
(
1
):
129
-
133
.
46.
Szturmowicz
M
,
Kacprzak
A
,
Wyrostkiewicz
D
, et al
.
Non-high risk PE in the patients with acute or exacerbated respiratory disease: the value of the algorithm based on D-dimer evaluation and Revised Geneva Score
.
Pneumonol Alergol Pol
.
2015
;
83
(
6
):
445
-
452
.
47.
Toulon
P
,
Lecourvoisier
C
.
D-dimer testing for suspected pulmonary embolism: performance of two rapid quantitative assays
.
Lab Med
.
2004
;
35
(
2
):
117
-
120
.
48.
Verschuren
F
,
Hainaut
P
,
Thys
F
, et al
.
ELISA D-dimer measurement for the clinical suspicion of pulmonary embolism in the emergency department: one-year observational study of the safety profile and physician’s prescription
.
Acta Clin Belg
.
2003
;
58
(
4
):
233
-
240
.
49.
Crane
S
,
Jaconelli
T
,
Eragat
M
.
Retrospective validation of the pulmonary embolism rule-out criteria rule in “PE unlikely” patients with suspected pulmonary embolism
.
Eur J Emerg Med
.
2018
;
25
(
3
):
185
-
190
.
50.
Pernod
G
,
Wu
H
,
de Maistre
E
, et al
.
Validation of STA-Liatest D-Di assay for exclusion of pulmonary embolism according to the latest clinical and Laboratory Standard Institute/Food and Drug Administration Guideline. Results of a multicenter management study
.
Blood Coag Fibrinolysis
.
2017
;
28
(
3
):
254
-
260
.
51.
Kabrhel
C
.
Outcomes of high pretest probability patients undergoing d-dimer testing for pulmonary embolism: a pilot study
.
J Emerg Med
.
2008
;
35
(
4
):
373
-
377
.
52.
Turan
O
,
Turgut
D
,
Gunay
T
,
Yilmaz
E
,
Turan
A
,
Akkoclu
A
.
The contribution of clinical assessments to the diagnostic algorithm of pulmonary embolism
.
Adv Clin Exp Med
.
2017
;
26
(
2
):
303
-
309
.
53.
Anderson
DR
,
Kahn
SR
,
Rodger
MA
, et al
.
Computed tomographic pulmonary angiography vs ventilation-perfusion lung scanning in patients with suspected pulmonary embolism: a randomized controlled trial
.
JAMA
.
2007
;
298
(
23
):
2743
-
2753
.
54.
Bajc
M
,
Albrechtsson
U
,
Olsson
CG
,
Olsson
B
,
Jonson
B
.
Comparison of ventilation/perfusion scintigraphy and helical CT for diagnosis of pulmonary embolism; strategy using clinical data and ancillary findings
.
Clin Physiol Funct Imaging
.
2002
;
22
(
6
):
392
-
397
.
55.
Hantous-Zannad
S
,
Esseghaier
S
,
Ridène
I
, et al
.
Acute pulmonary embolism: epidemiologic and tomodensitometric study
.
Tunis Med
.
2010
;
88
(
12
):
880
-
884
.
56.
Jiménez
D
,
Gómez
M
,
Herrero
R
, et al
.
Thromboembolic events in patients after a negative computed tomography pulmonary angiogram: a retrospective study of 165 patients
[in Spanish].
Arch Bronconeumol
.
2006
;
42
(
7
):
344
-
348
.
doi:https://doi.org/10.1016/S1579-2129(06)60544-2
57.
Macdonald
WB
,
Patrikeos
AP
,
Thompson
RI
,
Adler
BD
,
van der Schaaf
AA
.
Diagnosis of pulmonary embolism: ventilation perfusion scintigraphy versus helical computed tomography pulmonary angiography
.
Australas Radiol
.
2005
;
49
(
1
):
32
-
38
.
58.
Moores
L
,
Kline
J
,
Portillo
AK
, et al
.
Multidetector computed tomographic pulmonary angiography in patients with a high clinical probability of pulmonary embolism
.
J Thromb Haemost
.
2016
;
14
(
1
):
114
-
120
.
59.
Megyeri
B
,
Christe
A
,
Schindera
ST
, et al
.
Accuracy of computed tomography angiography in the detection of pulmonary embolism in patients with high body weight
.
Eur J Intern Med
.
2014
;
25
(
8
):
724
-
730
.
60.
Pérez de Llano
LA
,
Veres Racamonde
A
,
Ortiz Piquer
M
, et al
.
Safety of withholding anticoagulant therapy in patients who have clinically suspected pulmonary embolism and negative results on helical computed tomography
.
Respiration
.
2006
;
73
(
4
):
514
-
519
.
61.
Stein
PD
,
Fowler
SE
,
Goodman
LR
, et al;
PIOPED II Investigators
.
Multidetector computed tomography for acute pulmonary embolism
.
N Engl J Med
.
2006
;
354
(
22
):
2317
-
2327
.
62.
Subramaniam
RM
,
Blair
D
,
Gilbert
K
,
Coltman
G
,
Sleigh
J
,
Karalus
N
.
Withholding anticoagulation after a negative computed tomography pulmonary angiogram as a stand-alone imaging investigation: a prospective management study
.
Intern Med J
.
2007
;
37
(
9
):
624
-
630
.
63.
Garcia Bolado
A
,
Vicotria Barcena
M
,
Luis del Cura
J
,
Gorrino
O
,
Grande
D
.
Diagnostic indication for venous echo-Doppler of the lower limbs in the diagnosis of thromboembolic disease with suspected pulmonary thromboembolism
.
Radiología
.
2003
;
45
(
5
):
213
-
218
.
64.
Kim
KI
,
Müller
NL
,
Mayo
JR
.
Clinically suspected pulmonary embolism: utility of spiral CT
.
Radiology
.
1999
;
210
(
3
):
693
-
697
.
65.
Mac Gillavry
MR
,
Sanson
BJ
,
Büller
HR
,
Brandjes
DP
;
ANTELOPE-Study Group
.
Compression ultrasonography of the leg veins in patients with clinically suspected pulmonary embolism: is a more extensive assessment of compressibility useful?
Thromb Haemost
.
2000
;
84
(
6
):
973
-
976
.
66.
Turkstra
F
,
Kuijer
PM
,
van Beek
EJ
,
Brandjes
DP
,
ten Cate
JW
,
Büller
HR
.
Diagnostic utility of ultrasonography of leg veins in patients suspected of having pulmonary embolism
.
Ann Intern Med
.
1997
;
126
(
10
):
775
-
781
.
67.
Guilabert
JP
,
Manzur
DN
,
Tarrasa
MJT
,
Llorens
ML
,
Braun
P
,
Arques
MPB
.
Can multislice CT alone rule out reliably pulmonary embolism? A prospective study
.
Eur J Radiol
.
2007
;
62
(
2
):
220
-
226
.
68.
Perrier
A
,
Bounameaux
H
,
Morabia
A
, et al
.
Diagnosis of pulmonary embolism by a decision analysis-based strategy including clinical probability, D-dimer levels, and ultrasonography: a management study
.
Arch Intern Med
.
1996
;
156
(
5
):
531
-
536
.
69.
Blachere
H
,
Latrabe
V
,
Montaudon
M
, et al
.
Pulmonary embolism revealed on helical CT angiography: comparison with ventilation-perfusion radionuclide lung scanning
.
AJR Am J Roentgenol
.
2000
;
174
(
4
):
1041
-
1047
.
70.
Bounameaux
H
,
Cirafici
P
,
de Moerloose
P
, et al
.
Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism
.
Lancet
.
1991
;
337
(
8735
):
196
-
200
.
71.
Freitas
JE
,
Sarosi
MG
,
Nagle
CC
,
Yeomans
ME
,
Freitas
AE
,
Juni
JE
.
Modified PIOPED criteria used in clinical practice
.
J Nucl Med
.
1995
;
36
(
9
):
1573
-
1578
.
72.
Miron
MJ
,
Perrier
A
,
Bounameaux
H
, et al
.
Contribution of noninvasive evaluation to the diagnosis of pulmonary embolism in hospitalized patients
.
Eur Respir J
.
1999
;
13
(
6
):
1365
-
1370
.
73.
Spies
WG
,
Burstein
SP
,
Dillehay
GL
,
Vogelzang
RL
,
Spies
SM
.
Ventilation-perfusion scintigraphy in suspected pulmonary embolism: correlation with pulmonary angiography and refinement of criteria for interpretation
.
Radiology
.
1986
;
159
(
2
):
383
-
390
.
74.
van Rossum
AB
,
Pattynama
PM
,
Mallens
WM
,
Hermans
J
,
Heijerman
HG
.
Can helical CT replace scintigraphy in the diagnostic process in suspected pulmonary embolism? A retrolective-prolective cohort study focusing on total diagnostic yield
.
Eur Radiol
.
1998
;
8
(
1
):
90
-
96
.
75.
van Rossum
AB
,
Treurniet
FE
,
Kieft
GJ
,
Smith
SJ
,
Schepers-Bok
R
.
Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan
.
Thorax
.
1996
;
51
(
1
):
23
-
28
.
76.
Wells
PS
,
Anderson
DR
,
Rodger
M
, et al
.
Derivation of a simple clinical model to categorize patients probability of pulmonary embolism: increasing the models utility with the SimpliRED D-dimer
.
Thromb Haemost
.
2000
;
83
(
3
):
416
-
420
.
77.
Le Gal
G
,
Righini
M
,
Roy
PM
, et al
.
Value of D-dimer testing for the exclusion of pulmonary embolism in patients with previous venous thromboembolism
.
Arch Intern Med
.
2006
;
166
(
2
):
176
-
180
.
78.
Mos
IC
,
Douma
RA
,
Erkens
PM
, et al;
Prometheus Study Group
.
Diagnostic outcome management study in patients with clinically suspected recurrent acute pulmonary embolism with a structured algorithm
.
Thromb Res
.
2014
;
133
(
6
):
1039
-
1044
.
79.
Nijkeuter
M
,
Kwakkel-van Erp
H
,
Söhne
M
, et al;
Christopher Study Investigators
.
Clinically suspected acute recurrent pulmonary embolism: a diagnostic challenge
.
Thromb Haemost
.
2007
;
97
(
6
):
944
-
948
.
80.
van Belle
A
,
Büller
HR
,
Huisman
MV
, et al;
Christopher Study Investigators
.
Effectiveness of managing suspected pulmonary embolism using an algorithm combining clinical probability, D-dimer testing, and computed tomography
.
JAMA
.
2006
;
295
(
2
):
172
-
179
.

Author notes

The full-text version of this article contains a data supplement.

Supplemental data