In this issue of Blood, György and colleagues used multiple methods to characterize cell-derived microparticles (MPs) in the plasma and synovial fluid of arthritis patients and discovered that MPs and immune complexes (ICs) have overlapping biophysical properties (see figure).1 

MPs (also called microvesicles) are a heterogeneous population of membrane vesicles ranging between 100 and 1000 nm in diameter that are released from activated and apoptotic cells.2  They are present in various body fluids, such as plasma, synovial fluid, and urine.3  MPs have cell-surface receptors, cytosolic proteins, DNA, mRNA, and microRNA derived from their cell of origin and act as vectors of cell-cell communication.2,3  MP levels are increased in various diseases and have been proposed to play roles in many processes, including inflammation, thrombosis, and angiogenesis.2,3  They may also be useful biomarkers of disease.

Cells, MPs, and exosomes. Sizes of the different cells and particles and techniques used to study them are shown. (Professional illustration by Debra T. Dartez.)

Cells, MPs, and exosomes. Sizes of the different cells and particles and techniques used to study them are shown. (Professional illustration by Debra T. Dartez.)

Close modal

Various methods are used to analyze the biophysical properties of MPs, including flow cytometry, dynamic light scattering, atomic force microscopy, and electron microscopy. In addition, functional properties of MPs, such as their procoagulant activity, can be assessed using different assays. Each method has strengths and weaknesses.

The majority of studies use flow cytometry to characterize MPs in clinical samples. The strengths of this method are that it allows enumeration and determination of the cell origin. It is generally thought that flow cytometers can measure larger MPs (∼ 300-1000 nm; see figure). It should be noted that it is critical that MPs be labeled with directly conjugated antibodies and/or annexin V (which binds to phosphatidylserine exposed on the surface of many MPs). Early studies reported a 40-fold range in the number of platelet MPs in the plasma of healthy subjects. In response to this high level of variability, efforts have begun to standardize the quantification of MPs by flow cytometry. The first advance was the introduction of fluorescent-calibrated submicrometer beads. Indeed, newer flow cytometers can now distinguish 100- and 300-nm beads.4,5  However, these calibration beads have fundamentally different properties of forward and side scatter compared with biologic MPs, and the lower limit of detection of biologic MPs by flow cytometry is currently unclear. Despite these advances in analysis of MPs by flow cytometry, inherent limitations of this approach remain because most machines only analyze the larger MPs.

Dynamic light scattering, atomic force microscopy, and electron microscopy can be used to measure small particles, such as MPs and exosomes (see figure). Dynamic light scattering is excellent for determining size and quantification of particles but provides no information on the properties of the particle.4  In addition, it is more suited for analyzing homogeneous populations of particles rather than heterogeneous MP populations. Atomic force microscopy and electron microscopy allow for accurate determination of particle size and shape, but cannot be used for routine analysis of clinical samples.5  Lacroix and colleagues have recently described the strengths and weaknesses of the different techniques to measure MPs.6 

MPs are increased in the synovial fluid of rheumatoid arthritis patients and likely play a role in inflammation.7  A strength of the study by György and colleagues is that it used a combination of methods to analyze MPs.1  They found that MPs and ICs had similar biophysical properties, including size and light scattering. For instance, analysis by dynamic light scattering and atomic force microscopy showed that insoluble ICs and MPs both have sizes of 100-200 nm in diameter. Using flow cytometry, ICs were present in the forward scatter by side scatter gate used to define MPs. MPs and ICs could not be separated by differential centrifugation. However, the authors demonstrated that MPs from synovial fluid and plasma could be solubilized with detergent that did not affect ICs. One limitation of the study is that it used an older-style FACSCalibur flow cytometer.1  Nonetheless, these results suggest that previous studies, which did not discriminate MPs and ICs in the synovial fluid of rheumatoid arthritis patients, might have mistaken ICs for MPs.

The findings by György and colleagues highlight the limitations in the current techniques used to study MPs (when used alone) and raise the possibility that what is termed a MP in various body fluids may represent some other biologic or nonbiologic particles.1  Despite the excitement about MPs and their multiple roles in different biologic processes, there has been little attention paid to the techniques that are used to characterize and quantify these small particles. Variability in the measurement of MPs may also be due to a lack of standardization of preanalytical variables, such as collection of samples, storage, and centrifugation speeds.8,9  The development of new techniques and instruments, such as impedance-based flow cytometry and Nanosight tracking analysis, and the standardization of preanalytical and analytical variables to measure MPs, should greatly advance the field.

Conflict-of-interest disclosure: The authors declare no competing financial interests. ■

1
György
 
B
Módos
 
K
Pállinger
 
É
, et al. 
Detection and isolation of cell-derived microparticles are compromised by protein complexes resulting from shared biophysical parameters.
Blood
2011
, vol. 
117
 
4
(pg. 
e39
-
e48
)
2
Morel
 
O
Toti
 
F
Hugel
 
B
, et al. 
Procoagulant microparticles: disrupting the vascular homeostasis equation?
Arterioscler Thromb Vasc Biol
2006
, vol. 
26
 
12
(pg. 
2594
-
2604
)
3
Nieuwland
 
R
Sturk
 
A
Why do cells release vesicles?
Thromb Res
2010
, vol. 
125
 
suppl 1
(pg. 
S49
-
S51
)
4
Lawrie
 
AS
Albanyan
 
A
Cardigan
 
RA
Mackie
 
IJ
Harrison
 
P
Microparticle sizing by dynamic light scattering in fresh-frozen plasma.
Vox Sang
2009
, vol. 
96
 
3
(pg. 
206
-
212
)
5
Yuana
 
Y
Oosterkamp
 
TH
Bahatyrova
 
S
, et al. 
Atomic force microscopy: a novel approach to the detection of nanosized blood microparticles.
J Thromb Haemost
2010
, vol. 
8
 
2
(pg. 
315
-
323
)
6
Lacroix
 
R
Robert
 
S
Poncelet
 
P
Dignat-George
 
F
Overcoming limitations of microparticle measurement by flow cytometry.
Semin Thromb Hemost
2010
, vol. 
36
 
8
(pg. 
807
-
818
)
7
Beyer
 
C
Pisetsky
 
DS
The role of microparticles in the pathogenesis of rheumatic diseases.
Nat Rev Rheumatol
2010
, vol. 
6
 
1
(pg. 
21
-
29
)
8
Key
 
NS
Mackman
 
N
Tissue factor and its measurement in whole blood, plasma, and microparticles.
Semin Thromb Hemost
2010
, vol. 
36
 (pg. 
865
-
875
)
9
Orozco
 
AF
Lewis
 
DE
Flow cytometric analysis of circulating microparticles in plasma.
Cytometry A
2010
, vol. 
77
 
6
(pg. 
502
-
514
)
Sign in via your Institution