An enzyme-linked immunosorbent assay (ELISA) system for the quantitation of human monocytic colony-stimulating factor (hM-CSF) was established, which was based on the “dual antibody immunometric sandwich” principle using horse and rabbit polyvalent antibodies against human urinary colony-stimulating factor (CSF-HU). The minimal detectable level of hM-CSF was 10 U/mL, and the assays showed good reproducibility. As measured by this method, the average serum hM-CSF level of 20 normal adults was 540 +/- 110 U/mL (range, 300 to 800 U/mL). The peak of hM-CSF measured by ELISA was identical to that measured by bioassay when semipurified CSF-HU was fractionated by reversed-phase high performance liquid chromatography (HPLC). This method detected two types of hM-CSF, which had approximate molecular weights of 85 Kd (CSF-HU) and 45 Kd in human serum and urine; the ratio of 85:45 Kd was very high in serum and the amounts of the two types were nearly equal in urine. After anticancer chemotherapy, the serum hM- CSF level of one half of the patients with hematological malignancy was elevated according to the reduction in neutrophil number, while it was almost in the normal range in the other half of the patients, indicating the possibility that anticancer chemotherapy damaged the hM- CSF-producing cells. This ELISA method may be useful for monitoring the serum hM-CSF level after anticancer chemotherapy.

This content is only available as a PDF.
Sign in via your Institution