Platelet-associated IgG (PAIgG) was measured by a simple radial immunodiffusion technique using washed solubilized platelets and commercially available immunoplates. Subjects with normal platelet counts had PAIgG levels of 1.5--7.0 fg/platelet. Subjects with idiopathic immune thrombocytopenic purpura (ITP) had levels ranging from 5.7 to 70.5 fg/platelet. All patients with recurrent ITP and 85% of patients with acute ITP had elevated PAIgg. Elevated PAIgG was also found in 17% of patients with recovered ITP, 40% of patients with SLE and thrombocytopenia, 57% of patients with thrombocytopenia occurring during the course of septicemia, and 100% of patients with IgG myeloma in whom the serum IgG level was clearly elevated, regardless of the platelet count. The results are similar to reports that used more complex techniques.

This content is only available as a PDF.
Sign in via your Institution