To the editor:

In a recent issue of Blood, Ay and colleagues reported that elevated serum P-selectin levels predict venous thromboembolism (VTE) in cancer patients. They postulated that this marker could identify patients at risk who could benefit from prophylactic anticoagulation.1  Current guidelines do not recommend anticoagulant prophylaxis for ambulatory cancer patients, in part because a patient group at high enough risk for VTE to justify the risk of prophylaxis cannot be identified.2  Ay et al's study results have the potential for major clinical impact. However, we raise the question, “Is P-selectin ready for prime time?”

There are several issues we want to raise with respect to this cohort study. The first relates to the potential for ascertainment bias. Initially there were 812 patients; subsequently, 135 (15%) were excluded. The specific reasons for exclusion are not clear. Baseline serum-soluble P-selectin (sP-selectin) values were obtained for each patient at the start of the observation period. It is unclear whether the clinicians who conducted initial interviews, regular follow-up, and the diagnosis of VTE were blinded to test results.

Our second issue relates to selection of the time point of patient follow-up for relating the sP-selectin value to VTE incidence. Figure 1 of Ay et al illustrates the cumulative incidence of VTE over 2 years.1  We wonder if the authors chose to analyze the values at the 6-month point based on their observation that this is when the 2 curves were maximally separated (11.9% vs 3.7%) and all of the events in the high sP-selectin group, but only about one-half of the events in the other group, had occurred. A better time to estimate the effect is when all events have occurred. Thus, if the 12-month time point is selected, the cumulative incidences of VTE for the 2 groups are 11.9% versus 5.8%, resulting in a 2-fold rather than 3-fold risk.

Finally, it is unclear whether the choice of the 75th percentile to dichotomize the sP-selectin scale was predetermined or data-driven. We suggest that use of a receiver operating characteristic (ROC) curve would have been more appropriate in illustrating the performance of the sP-selectin value using multiple cutoffs. It is of interest that the authors used this method in an earlier paper on sP-selectin.3 

sP-selectin clearly has limitations as a predictor of risk. Of the 173 patients in the upper quartile of sP-selectin, we calculated that 19 had VTE compared with 25 of 514 in the lower quartiles. With this cut-point, the sensitivity of sP-selectin is 43%, the specificity is 76%, and the negative predictive value is 95%, but the positive predictive value is only 11%. Hence, the test would be associated with a large number of false positives, limiting its potential for identifying candidates for prophylaxis. The results of Ay et al are encouraging but require validation in a larger prospective cohort.

Conflict-of-interest disclosure: The authors declare no competing financial interests.

Correspondence: Dr Mark Levine, c/o Henderson Research Centre, 711 Concession Street, Hamilton, ON, Canada L8V 1C3; e-mail: mlevine@mcmaster.ca.

1
Ay
 
C
Simanek
 
R
Vormittag
 
R
High plasma levels of soluble P-selectin are predictive of venous thromboembolism in cancer patients: results from the Vienna Cancer and Thrombosis Study (CATS).
Blood
2008
, vol. 
112
 (pg. 
2703
-
2708
)
2
Lyman
 
G
Khorana
 
A
Falanga
 
A
American Society of Clinical Oncology Guideline: recommendations for venous thromboembolism prophylaxis and treatment in patients with cancer.
J Clin Oncol
2007
, vol. 
25
 (pg. 
5490
-
5505
)
3
Ay
 
C
Jungbauer
 
LV
Sailer
 
T
, et al. 
High concentrations of soluble P-selectin are associated with risk of venous thromboembolism and the p-selectin Thr715 variant.
Clin Chem
2007
, vol. 
53
 (pg. 
1235
-
1243
)
Sign in via your Institution