A quantitative immunofluorescence platelet-associated immunoglobulins (PA-IgG) assay was used to detect alloimmunity to platelets in 8/12 multitransfused patients and to perform platelet crossmatching in the 8 alloimmunized patients. The correct separation of multitransfused patients into alloimmune and nonalloimmune groups was substantiated with chromium-51-labeled platelet survival studies. For 5 alloimmunized patients, compatible and incompatible donor platelets were demonstrated by PA-IgG crossmatching and were confirmed by platelet survival studies. With the other 3 alloimmunized patients, only studies with 5 of these incompatible donor platelets showed markedly reduced survival times on 4 occasions. PA-Igg compatible donor platelets survived 3.5- 8.7 days, while PA-IgG incompatible platelets showed survival times of 0.1–2.4 days. Overall, PA-IgG testing correctly indicated survival results on 15/17 occasions (88%), whereas platelet aggregation, serotonin release, and lymphocytotoxicity testing showed correct predictions for only 41%-59% of the survival studies. PA-IgG testing predicted which times, thus indication patients with platelet-specific alloantibodies. the PA-IgG assay provides a sensitive method to detect platelet alloantibodies and to perform platelet crossmatching, which can complement HLA typing in the selection of donor platelets for alloimmunized patients.

This content is only available as a PDF.