Figure 2
Figure 2. Force curves. (A-B) Schematic illustrations. (C-F) Example data. The PZT retracted the cantilever base linearly to a preset position (B,C-F, red lines and right ordinate) and then held it there to stretch the molecules with a constant force (A,C-F, blue curves and left ordinate) to measure various times characteristic of molecular structural destabilization or rupture induced by this force. (C) A curve of 2 force drops (indicated by 2 in the first subscript of tij) and 2 periods at constant force (indicated by 1 and 2 in the second subscript of tij) with respective durations of time-to-destabilization t21 and time-to-rupture t22. Force drop triggered via feedback control further retraction of the PZT attempting to bring the force back to the preset level, which was successful after the first force drop by retracting a distance ld but was unsuccessful after the second force drop even by long-distance retraction, indicating rupture. (D) A curve of 2 force drops but only 1 period at constant force with duration of t21 but no t22 resulting from premature rupture occurred before force was resumed to the preset level. (E) A curve of 2 force drops but only 1 period at constant force with duration of t22 but no t21 resulting from premature destabilization occurred before arriving at the preset force. (F) A curve of 1 force drop (indicated by 1 in the first subscript of tij, i, j = 1 or 2) and 1 period at constant force (indicated by 1 in the second subscript of tij) with duration of time-to-rupture t11. Data shown were acquired by GPIbα-pulling, but those obtained by CR1-pulling were similar.

Force curves. (A-B) Schematic illustrations. (C-F) Example data. The PZT retracted the cantilever base linearly to a preset position (B,C-F, red lines and right ordinate) and then held it there to stretch the molecules with a constant force (A,C-F, blue curves and left ordinate) to measure various times characteristic of molecular structural destabilization or rupture induced by this force. (C) A curve of 2 force drops (indicated by 2 in the first subscript of tij) and 2 periods at constant force (indicated by 1 and 2 in the second subscript of tij) with respective durations of time-to-destabilization t21 and time-to-rupture t22. Force drop triggered via feedback control further retraction of the PZT attempting to bring the force back to the preset level, which was successful after the first force drop by retracting a distance ld but was unsuccessful after the second force drop even by long-distance retraction, indicating rupture. (D) A curve of 2 force drops but only 1 period at constant force with duration of t21 but no t22 resulting from premature rupture occurred before force was resumed to the preset level. (E) A curve of 2 force drops but only 1 period at constant force with duration of t22 but no t21 resulting from premature destabilization occurred before arriving at the preset force. (F) A curve of 1 force drop (indicated by 1 in the first subscript of tij, i, j = 1 or 2) and 1 period at constant force (indicated by 1 in the second subscript of tij) with duration of time-to-rupture t11. Data shown were acquired by GPIbα-pulling, but those obtained by CR1-pulling were similar.

Close Modal

or Create an Account

Close Modal
Close Modal