Figure 6
Figure 6. Adhesion of transgenic mouse platelets to VWF under high shear conditions. (A) Transgenic mouse blood was perfused over human VWF at a rate of 1800 s−1, followed by incremental increases in shear rate to a maximum of 20 000 s−1. Quantitation of the number of adherent platelets at each shear rate demonstrated a significant reduction in the number of hGPIbαFW platelets able to remain adherent at shear rates of 10 000 s−1 and above compared with hGPIbαWT as mean (± SEM) for n = 6 experiments. *P < .05. (B) Rolling velocity was analyzed from the same experiments as in panel A. At shear rates of 3000 s−1 and above, hGPIbαFW platelets rolled significantly faster that hGPIbαWT platelets for n = 6 experiments. *P < .05, **P < .01. Note that the rolling velocity at 20 000 s−1 was not significantly different because there were too few hGPIbαFW platelets remaining adherent to analyze. (C) Transgenic mouse blood was perfused over human VWF at 5000, 10 000, or 20 000 s−1 and the number of platelets adhering from the bulk flow was quantitated over at least 5 fields as the mean (± SEM) from 3 independent experiments. There was no significant difference between the number of adherent hGPIbαWT and hGPIbαFW platelets at any of the shear rates tested.

Adhesion of transgenic mouse platelets to VWF under high shear conditions. (A) Transgenic mouse blood was perfused over human VWF at a rate of 1800 s−1, followed by incremental increases in shear rate to a maximum of 20 000 s−1. Quantitation of the number of adherent platelets at each shear rate demonstrated a significant reduction in the number of hGPIbαFW platelets able to remain adherent at shear rates of 10 000 s−1 and above compared with hGPIbαWT as mean (± SEM) for n = 6 experiments. *P < .05. (B) Rolling velocity was analyzed from the same experiments as in panel A. At shear rates of 3000 s−1 and above, hGPIbαFW platelets rolled significantly faster that hGPIbαWT platelets for n = 6 experiments. *P < .05, **P < .01. Note that the rolling velocity at 20 000 s−1 was not significantly different because there were too few hGPIbαFW platelets remaining adherent to analyze. (C) Transgenic mouse blood was perfused over human VWF at 5000, 10 000, or 20 000 s−1 and the number of platelets adhering from the bulk flow was quantitated over at least 5 fields as the mean (± SEM) from 3 independent experiments. There was no significant difference between the number of adherent hGPIbαWT and hGPIbαFW platelets at any of the shear rates tested.

Close Modal

or Create an Account

Close Modal
Close Modal