Table 4.

Detection of BMI

Detection of BMI by PET/CT alone using BMB as reference standard*Detection of BMI when using combined BMB and PET/CT as reference standard
Absolute nos.Percentage (95% CI)PET/CTPercentage (95% CI)BMBPercentage (95% CI)
Sensitivity 46/81 57 (45-68) 78/(78 + 35) 69 (60-77) 81/(81 + 32) 72 (62-80) 
Specificity 148/180 82 (76-84) N/A N/A N/A N/A 
PPV 46/(46 + 32) 59 (47-70) N/A N/A N/A N/A 
NPV 148/183 81 (74-86) 148/183 81 (74-86) 148/(148 + 32) 82 (76-88) 
Accuracy (46 + 148)/261 74 (69-80) (46 + 148 + 32)/261 87 (82-90) (46 + 148 + 35)/261 88 (83-91) 
Detection of BMI by PET/CT alone using BMB as reference standard*Detection of BMI when using combined BMB and PET/CT as reference standard
Absolute nos.Percentage (95% CI)PET/CTPercentage (95% CI)BMBPercentage (95% CI)
Sensitivity 46/81 57 (45-68) 78/(78 + 35) 69 (60-77) 81/(81 + 32) 72 (62-80) 
Specificity 148/180 82 (76-84) N/A N/A N/A N/A 
PPV 46/(46 + 32) 59 (47-70) N/A N/A N/A N/A 
NPV 148/183 81 (74-86) 148/183 81 (74-86) 148/(148 + 32) 82 (76-88) 
Accuracy (46 + 148)/261 74 (69-80) (46 + 148 + 32)/261 87 (82-90) (46 + 148 + 35)/261 88 (83-91) 

N/A, not applicable.

*

Note that this represents an unrealistic worst-case scenario, assuming that all focal FDG uptake outside of the location of BMB was false-positive. These data are only reported for completeness.

Values represent absolute numbers, and values in parentheses represent the sum of absolute numbers shown in Table 3 used for calculations as per standard formulas for sensitivity, specificity, PPV, NPV, and accuracy.

Missing reference for the false-positives.