Table 1

Immunoassays for diagnosis of HIT: available classes of assays, antibody specificities, thresholds, test variations, and manufacturers

Classes of assaysAntibody specificityThresholdTest variationManufacturer (names of tests)
ELISA Polyspecific Low* High heparin dose confirmation step In-house assays 
IgG specific Intermediate  GTI Diagnostics, Waukesha, WI (GTI-PF4; HAT; PF4-Enhanced; GTI-IgG) 
 High  Hyphen-BioMed, Neuville-Sur-Oise, France (Zymutest HIA IgGAM; Zymutest HIA IgG) 
   Diagnostica Stago, Asnières-sur-Seine, France (Asserachrom HIPA) 
   Gen-Probe (Gen-Probe PF4)§ 
   Technoclone GmbH, Vienna, Austria (Technozym) 
PaGIA Polyspecific Low||  Diamed, Cressier sur Morat, Switzerland (ID-H/PF4 PaGIA) 
Intermediate 
PIFA Polyspecific Positive/negative  Akers Biosciences Inc, Thorofare, NJ (HealthTEST) 
Lateral flow immunoassay IgG specific Positive/negative  Diagnostica Stago (STic EXPERT HIT); Milenia Biotec, Giessen, Germany (Milenia QuickLine HIT) 
CLIA Polyspecific Low#  Instrumentation Laboratory, Bedford, MA (HemosIL AcuStar HIT-Ab; HemosIL AcuStar HIT-IgG) 
IgG specific Intermediate**  
 High††  
Latex agglutination assay Polyspecific Low‡‡  Instrumentation Laboratory (HemosIL HIT-Ab) 
Classes of assaysAntibody specificityThresholdTest variationManufacturer (names of tests)
ELISA Polyspecific Low* High heparin dose confirmation step In-house assays 
IgG specific Intermediate  GTI Diagnostics, Waukesha, WI (GTI-PF4; HAT; PF4-Enhanced; GTI-IgG) 
 High  Hyphen-BioMed, Neuville-Sur-Oise, France (Zymutest HIA IgGAM; Zymutest HIA IgG) 
   Diagnostica Stago, Asnières-sur-Seine, France (Asserachrom HIPA) 
   Gen-Probe (Gen-Probe PF4)§ 
   Technoclone GmbH, Vienna, Austria (Technozym) 
PaGIA Polyspecific Low||  Diamed, Cressier sur Morat, Switzerland (ID-H/PF4 PaGIA) 
Intermediate 
PIFA Polyspecific Positive/negative  Akers Biosciences Inc, Thorofare, NJ (HealthTEST) 
Lateral flow immunoassay IgG specific Positive/negative  Diagnostica Stago (STic EXPERT HIT); Milenia Biotec, Giessen, Germany (Milenia QuickLine HIT) 
CLIA Polyspecific Low#  Instrumentation Laboratory, Bedford, MA (HemosIL AcuStar HIT-Ab; HemosIL AcuStar HIT-IgG) 
IgG specific Intermediate**  
 High††  
Latex agglutination assay Polyspecific Low‡‡  Instrumentation Laboratory (HemosIL HIT-Ab) 

GTI, Genetic Testing Institute.

*

≤OD 0.7.

Between OD 0.8 and 1.4.

>OD 1.4.

§

Technically identical with GTI assay.

||

Positive/negative.

Titer 2 to 3.

#

1.0 U/mL.

**

1.0-2.8 U/mL.

††

>2.8 U/mL.

‡‡

>3.85 U/mL.