Table 3

Univariate analysis of different cutoff values of serum ferritin and the risk for sinusoidal obstruction syndrome

Ferritin serum level, ng/mLSOS, no. (%)
POdds ratio (95% CI)ROC curve analysis
Yes n=88No n=339AUCP*
623 (median) 54 (61) 159 (47) .02 1.80 (1.08-2.99) 0.572 .04 
1000 43 (49) 94 (28) < .001 2.49 (1.50-4.14) 0.606 .002 
1500 30 (34) 56 (16) < .001 2.61 (1.49-4.57) 0.588 .01 
2000 21 (24) 41 (12) .005 2.28 (1.21-4.27) 0.559 .09 
3000 11 (12) 14 (4) .003 3.32 (1.34-8.13) 0.542 .23 
4000 7 (8) 7 (2) .01 4.10 (1.25-13.44) 0.529 .39 
Ferritin serum level, ng/mLSOS, no. (%)
POdds ratio (95% CI)ROC curve analysis
Yes n=88No n=339AUCP*
623 (median) 54 (61) 159 (47) .02 1.80 (1.08-2.99) 0.572 .04 
1000 43 (49) 94 (28) < .001 2.49 (1.50-4.14) 0.606 .002 
1500 30 (34) 56 (16) < .001 2.61 (1.49-4.57) 0.588 .01 
2000 21 (24) 41 (12) .005 2.28 (1.21-4.27) 0.559 .09 
3000 11 (12) 14 (4) .003 3.32 (1.34-8.13) 0.542 .23 
4000 7 (8) 7 (2) .01 4.10 (1.25-13.44) 0.529 .39 

SOS indicates sinusoidal obstruction syndrome; 95% CI, 95% confidence interval; ROC, receiver operating characteristic; and AUC, area under the curve.

*

Probability that the area is different from .5.