Table 1.

Thrombin generation is similar in F13a+/+, F13a+/−, and F13a−/− mice

PPPPRP
F13a+/+F13a+/−F13a−/−F13a+/+F13a+/−F13a−/−
Lag time, min 1.6 ± 0.2 1.7 ± 0.1 1.6 ± 0.1 2.3 ± 0.2 2.3 ± 0.1 2.33 ± 0.2 
Time to peak, min 3.6 ± 0.5 3.7 ± 0.1 3.5 ± 0.1 5.6 ± 0.3 6.0 ± 0.4 4.9 ± 0.2 
Velocity, nM/min 35.8 ± 2.6 33.8 ± 1.2 34.1 ± 2.6 18.0 ± 2.7 13.8 ± 3.3 22.3 ± 5.3 
Peak thrombin, nM 70.1 ± 2.9 66.7 ± 1.5 65.3 ± 3.9 55.2 ± 6.0 46.4 ± 6.6 52.7 ± 3.7 
Endogenous thrombin potential, nM*min 387.7 ± 34.4 417.5 ± 68.7 284.6 ± 18.5 804.8 ± 164.6 621.0 ± 63.1 611.4 ± 50.0 
PPPPRP
F13a+/+F13a+/−F13a−/−F13a+/+F13a+/−F13a−/−
Lag time, min 1.6 ± 0.2 1.7 ± 0.1 1.6 ± 0.1 2.3 ± 0.2 2.3 ± 0.1 2.33 ± 0.2 
Time to peak, min 3.6 ± 0.5 3.7 ± 0.1 3.5 ± 0.1 5.6 ± 0.3 6.0 ± 0.4 4.9 ± 0.2 
Velocity, nM/min 35.8 ± 2.6 33.8 ± 1.2 34.1 ± 2.6 18.0 ± 2.7 13.8 ± 3.3 22.3 ± 5.3 
Peak thrombin, nM 70.1 ± 2.9 66.7 ± 1.5 65.3 ± 3.9 55.2 ± 6.0 46.4 ± 6.6 52.7 ± 3.7 
Endogenous thrombin potential, nM*min 387.7 ± 34.4 417.5 ± 68.7 284.6 ± 18.5 804.8 ± 164.6 621.0 ± 63.1 611.4 ± 50.0 

Thrombin generation was measured by calibrated automated thrombography. Data show mean ± SEM and were analyzed by ANOVA with Dunnett’s post-hoc test (n = 4-6).